4. INSTALLATION
26
Combination of transducer, thru-hull pipe and tank
Output
(W)
Frequency
(kHz)
Ship type
Transducer
Thru-hull pipe
Tank
1k/1k
50/200
Steel
50/200-1T
TFB-5000(1)
T-603
FRP
–
T-603F
1k/2k
50/200
Steel
50B-9B
200B-8/8B
TWB-6000(2)
T-658
FRP
2k/2k
50/200
Steel
50BL-12HR
200B-8/8B
TFB-7000(2)
T-693
FRP
TRB-1100(2)
T-693-F
3k/3k
50/200
Steel
50BL-24HR
200B-12H
TFB-7000(2)
T-683
FRP
TRB-1100(2)
T-683-F
1k
50
Steel
50B-6/6B
TFB-5000(1)
T-605
FRP
TRB-1000(1)
T-605-F
Steel
50B-9B
TFB-5000(1)
T-603
FRP
TRB-1000(1)
T-603-F
200
Steel
200B-5S
TFB-5000(1)
T605
FRP
TRB-1000(1)
T-605-F
2k
50
Steel
50BL-12HR
TFB-5000(1)
T-702
FRP
TRB-1000(1)
T-702-F
200
Steel
200B-8/8B
TFB-5000(1)
T-608
FRP
TRB-1000(1)
T-608-F
3k
50
Steel
50BL-24HR
TFB-4000(1)
T-616
FRP
TRB-1000(1)
T-616-F
200
Steel
200B-12H
TFB-5000(1)
T-615
FRP
TRB-1000(1)
T615-F
Summary of Contents for FCV-288
Page 1: ......