1. OPERATION
12
4) Select the [From] that is below [Depth]
and press the
ENTER
key.
5) Enter the width of the alarm and press
the
ENTER
key.
The alarm marker appears at the
starting point for the alarm. (The
marker appears only when the corre-
sponding alarm is active.) The starting
depth for the Fish School alarms is the
transducer position. For the Bottom
Lock alarm the starting depth is the
distance from the bottom.
6) Select [Span] and press the
ENTER
key.
7) Enter the alarm width and press the
ENTER
key.
Water temperature
1) Select [Inside] or [Outside] as appli-
cable and press the
ENTER
key.
2) Select [From] and
press the
ENTER
key.
3) Enter the starting tem-
perature for the alarm
and press the
ENTER
key.
4) Select [Span] and
press the
ENTER
key.
5) Enter the width for the
alarm and press the
ENTER
key.
Bottom
1) Set [Bottom] to [On] and press the
EN-
TER
key.
2) Select [From] and
press the
ENTER
key.
3) Set the starting depth
and press the
ENTER
key.
4) Select [Span] and
press the
ENTER
key.
5) Set the width of the
alarm and press the
ENTER
key.
10. Press the
MENU ESC
key
to show the [Fish Alarm] setting window.
11. Select [Alarm] and press the
ENTER
key.
12. Select [On] and press the
ENTER
key.
Note 1:
To disable an alarm, select [Off] at
step 12 in the above procedure.
Note 2:
The default alarm settings can be re-
stored. Open the [Fish Alarm] setting window,
select [Reset?], press the
ENTER
key, select
[Yes] and press the
ENTER
key.
Fish School
alarm
Bottom Fish
alarm
Alarm marker
- Fish School, Bottom: Right side
- Bottom lock: Center
Starting
depth
Alarm range
(width from
starting depth)
Fish School
alarms
Bottom Fish
alarm
Summary of Contents for FCV-288
Page 1: ......
Page 54: ...D 1 27 Apr 2012 Y NISHIYAMA...