19
3.
INITIAL SETTINGS
3.1
DIP Switch Setting
The DIP switch S2 sets up the system according to the equipment connected. In the default setting
all switches (1-8) are OFF. The DIP switch S3 should not be adjusted; leave all switches in the
OFF position.
DIP switch S2 description
Switch
No.
Function
Setting
1
IP mode
OFF
: FIxed (static) IP address. Set the IP address
with switch #2, referring to the table below.
ON
: Use IP address assigned by DHCP.
2
IP address no.
OFF
: Set the #1 switch to OFF to set IP address. See
the table on the next page for IP address assignment.
3
Restore default settings (other than
LAN and transducer)
See section 4.3.
4
Restore ALL default settings
See section 4.3.
5 - 6
Keep these switches in the OFF position.
7
No use
8
No use
WARNING
Do not open the equipment unless totally
familiar with electrical circuits.
Only qualified personnel should work inside
the equipment.
DIP Switches
(factory settings)
1-8
ON
OFF
S3
S2
4-1
OFF
ON
Summary of Contents for DFF1-UHD