2. WIRING
7
2.2
Transducer Cable, Cable for External KP (option)
If the external KP is not to be connected, do only the applicable procedures in sections 2.2.1 and
2.2.2.
The KP from an echo sounder or sonar can be connected to this network fish finder to synchronize
transmission (to prevent interference). Use the optional Connector Kit for TX Sync (Type, OP02-
86, Code No. 001-205-780) and cable MPYC-4 (or MPYC-2) for the connection. (The MPYC-4 is
a Japan Industrial Standard (JIS) cable. If not available locally, see the Appendix 2 for the equiv-
alent cable.)
Connector kit for TX sync
2.2.1
How to process the cables
Note:
The label on the transducer cable can be removed if it interferes with treatment of the cable.
How to process the transducer cable
CM265LH
B265LH
Name
Type
Code No.
Qty
Upset UI Screw-B
M4
×
20
000-163-756-10
2
Super Gland
MGB20M-12B
000-177-248-10
1
PH Connector Assembly
02-1097 (4P)
001-206-000
1
Cable Clamping Plate
02-167-1528
100-379-090-10
1
Rainproofing Panel KP
02-167-1529
100-379-100-10
1
EMI Core
GRFC-10
000-177-010-10
1
Crimp-on Lug
NCW-1.25
000-157-213-10
4
Braided shield
Taping
Sheath
Extract braided shield and wrap it around sheath.
(This part lies in cable clamp.)
Extract cores from here and cut inclusion.
6
20
Approx. 100
Approx. 100
Vinyl tape (one turn)
㪍
20
Wind shield around cable.
(This part lies in cable clamp.)
Extract cores from here and
cut inner materials.
Put unused wires (3)
in vinyl tubing (local
supply) for insulation.
Summary of Contents for DFF1-UHD
Page 1: ...NETWORK FISH FINDER DFF1 UHD OPERATOR S MANUAL www furuno com Model...
Page 2: ......
Page 34: ...7 Dec 2012 Y NISHIYAMA...
Page 38: ......
Page 39: ......