background image

RVC-7W

- 7 -

SYMM ETRICAL POWER ISOLATION TRANSFORMER

AC POWER CONDITIONER

RVC-7W   REFERENCE VIDEO CONDITIONER

INPUT:     120VAC  60HZ.  7AMP   1O

OUTPUT: 120VAC  1O  ( 60VAC LINE / 60VAC NEUTRAL REFERENCED TO OUTPUT
                 GROUND)  60HZ.  7AMP MAX.   GFI PROTECTED

CAUTION!
RISK OF ELECTRIC SHOCK.  DO NOT REMOVE FRONT PANEL / COVER.  REFER
SERVICING TO QUALIFIED SERVICE PERSONNEL. TO REDUCE RISK OF ELECTRICAL
SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN AND MOISTURE.

AVIS!
CIRCUIT  COMMUN ISOLE DE LA MASSE A LA SORTIE.   MEME SI  LE COURANT A
LA SORTIE EST MUNI DE PROTECTION  GFI, NE  JAMAIS TOUCHER  LES FILS
EXPOSES  OU LES PARTIES EN METAL SANS TESTER POUR LA  PRESENSE  DE
TENSIONS  A.C.!

ETL  LISTED 3041249 CONFORMS TO  ANSI /UL #1012
CERTIFIED TO CAN/ CSA E335-1/3E-94

L

N

adjusted, remove the chassis and install the 

cable clamps. We do not supply these, as they 

are very common at any hardware or electrical 

supply store, and individual installers will have 

their preferences as to model and manufac-

ture. All we (and your local inspector) require is 

that the cable clamps be standard CSA, C-UL, 

C-ETL, or NRTL-C recognized cable clamps 

(virtually all of them are at least one of these). 

The larger hole on the bottom surface is for the 

signal wiring and cables. It requires a 1” con-

duit cable clamp. The smaller hole to the right 

is for the incoming AC wiring. It requires a 3/4” 

conduit cable clamp.
NOTE: The hole, antechamber, and front panel 

cutout for the signal wiring is for convenience and 

to neatly dress these wires and cables. There is 

no connection  to anything within the chassis. 
16.  Once the conduit cable clamps are in place, 

dress the signal wiring through the large clamp, 

and the A.C. wiring through the small clamp. 

Since the chassis is just over 40lbs. it may be 

necessary to have a helper hold the unit during 

this operation, or place it on a stand or table im-

mediately below the wall cut-out.
NOTE: It is absolutely imperative for safety that 

the incoming AC wiring be DISENGAGED dur-

ing installation.  The AC Power for the RVC-7W 

MUST be supplied via a breaker panel that 

uses a D.P.S.T. circuit breaker switched to the 

OFF position. Spacing of the live contacts on 

this switch must be at least 3 m.m.  (virtually all 

switched circuit breakers will meet this criteria).  

DO NOT fail to check this prior to handling, 

dressing, and installing these wires! 
17. With the wires properly dressed through and 

secured by the clamps, place the chassis on the 

brackets for the remainder of the installation.
18. Trim the insulation off the wires (ap-

proximately 3/8” for Line and Neutral). Place 

the Neutral wire into the A.C. terminal block 

marked “N”, (bottom opening) and secure with 

a slotted screwdriver. Place the Line wire into 

the A.C. terminal block marked “L”, (bottom 

opening) and secure with a slotted screwdriver. 

The ground wire must be surely fastened to 

the green 10-32 slotted screw on the bottom. 

A listed ring lug, appropriate for the wire gauge 

is recommended, though wrapping a solid core 

wire around the screw is acceptable in some 

INTRODUCTION

FEATURES

DESCRIPTION

INSTALLATION

SAFETY

SPECS

Summary of Contents for RVC-7W

Page 1: ...AC Power Conditioner 7 Amp In Wall Featuring Isolated Symmetrically Balanced Power and Narrow Bandwidth Technology O w n e r s M a n u a l IN T R O D U C T I ONS FEATURES DESCRIPTION INSTALLATION SAFE...

Page 2: ...in excess of 40dB at virtually all video frequencies up to 1 GHz Maintenance free transient voltage surge suppression protects your valuable equip ment while virtually eliminating costly service calls...

Page 3: ...LLATION PRELIMINARY Before unpacking your unit inspect the box and packing materials for any obvious dam age If internal damage is likely contact the carrier who delivered the unit before proceed ing...

Page 4: ...r These are supplied with each RVC 7W and are also supplied as a separate accessory HRKIT RVCW 4 Now it s time to mark the position of the pilot holes for the 10 screws In a retro t the chal lenge wil...

Page 5: ...h with the inside of the wall assuming the devices edge starts precisely at zero See new construction di rectly above for pilot hole depth marks with standard 1 2 and 5 8 wall thickness 8 At this poin...

Page 6: ...o the right should not be loosened It is a grounding strap screw and is not used to attach the front panel to the chassis See g 3 13 Lift the front panel from the chassis don t lose the screws in the...

Page 7: ...s for convenience and to neatly dress these wires and cables There is no connection to anything within the chassis 16 Once the conduit cable clamps are in place dress the signal wiring through the lar...

Page 8: ...studs This will off set any wobble or mechanical stress that might otherwise occur Use these only if necessary GROUND FAULT INTERRUPTER GFCI As the RVC 7W incorporates Isolated Sym metrically Balance...

Page 9: ...not be attempted with live AC wiring Input wiring must come from a switched electrical panel that has been disengaged Do not disassemble or modify in any way No user serviceable parts inside Keep away...

Page 10: ...Damaged equipment must remain available for inspec tion until the claim is nalized The Connected Equipment Warranty is also in effect for a period of three years unless the Purchaser does not complete...

Page 11: ...n of Furman with respect to the product If any part of this Limited Warranty is determined to be void or illegal the remainder shall remain in full force and effect Warranty claims should be accompani...

Page 12: ...Clamping Voltage 324V 10 1000 65 000 Watts 20uS Test 300 000 Watts Peak Power Handling Noise Attenuation Transverse and Common Mode Greater than 60dB 1 MHz 1 GHz Transformer Breakdown voltage 1500V mi...