background image

Model 

Weight

 

Dimensions (H x W x D)

 

UPS2000-MBS-16A 

1.5 kg 

50 mm x 438 mm x 80 mm 

Copyright © Huawei Technologies Co., Ltd. 2016. All rights reserved. 

Overview 

To safely operate this unit, read and follow all instructions carefully. Read this manual 
thoroughly before attempting to unpack, install, or operate. You may keep this quick guide for 
further reference. 
1. The unit must be used indoor only. 
2. Do not place the unit near liquid or in an excessively damp environment. 
3. Do not place the unit directly in the sun or near a hot source.  
4. Do not let liquid or foreign objects enter the unit. 
5. Ground the unit using a 2P + ground outlet. 
6. When installing the unit, ensure that the sum of the leakage currents of the unit and the 

devices it powers does not exceed 3.5 mA. 

NOTICE

(1) Slave outlets 

(2) Master outlets 

(3) Power indicator 

(4) Slave on indicator 

(5) Bypass switch 

(6) Outlet for UPS 
output 

(7) Outlet for UPS 
input 

(8) AC input 

(9) Circuit breaker 

(10) Master/slave 
function switch 

Issue: 01 
Date: 2016-03-25 

UPS2000-MBS-16A PDU & 
Maintenance Bypass Switch Module 

Quick Guide 

 

Remove the unit from the shipping package and check it for damage that may occur during 
transportation. Notify the carrier and place of purchase if any damage is found. The shipping 
package contains: 
• PDU & Maintenance bypass switch module x 1 
• Packing list x 1 
• Quick guide x 1 
• Screws and mounting brackets 

• Mains power cord x 1 
• Power cord for 1 kVA/2 kVA UPS x 2 
• Power cord for 3 kVA UPS x 3 
• Output power cables x 2 

Inspection 

Summary of Contents for UPS2000-MBS-16A

Page 1: ...talling the unit ensure that the sum of the leakage currents of the unit and the devices it powers does not exceed 3 5 mA NOTICE 1 Slave outlets 2 Master outlets 3 Power indicator 4 Slave on indicator 5 Bypass switch 6 Outlet for UPS output 7 Outlet for UPS input 8 AC input 9 Circuit breaker 10 Master slave function switch Issue 01 Date 2016 03 25 UPS2000 MBS 16A PDU Maintenance Bypass Switch Modu...

Page 2: ... G 2KRTL when connecting UPS2000 G 1KRTL 1KRTS 2KRTS Refer to cable connection of UPS2000 G 3KRTL when connecting UPS2000 G 3KRTS 3 3 kVA UPS output form factor terminal or C20 varies with different actual models NOTE UPS2000 G 2KRTL UPS2000 G 3KRTL 2 Installing the Unit 3 Rack mounting Scenario Front Rear NOTICE When installing ensure that the PDU rear panel is aligned with the UPS rear panel C19...

Page 3: ...he mains is normal The Power indicator will turn off when there is a power failure 1 The master slave function is disabled by default Ensure that the master slave function switch is on the disable status before operation 2 Only when the master slave function is enabled loads connected to slave outlets will be shut down after load is detected lower than 10 W in master outlet 3 Master slave function...

Page 4: ...this time all connected devices are powered by the mains directly Turn off the UPS and disconnect two cables connected to the UPS Then you can maintain the UPS After maintaining the UPS ensure that the UPS operates properly Reconnect the UPS to the unit by following the installation section Verify that the Power indicator is on Turn on the UPS then transfer the rotary bypass switch from MBS to UPS...

Reviews: