Connecting Equipment 
 

4.2 

Connecting to the Wall Outlet 
 

4.3 

Plug Computer into Master Outlet 

Plug Peripherals into Slave Outlets 

When the computer is turned off, the master outlet shuts off power to the slave outlets. 
However, when the computer goes into sleep mode or the power consumption of connected 
device to the master outlet is below 10 W, the master outlet may not properly recognize the 
reduced power level. 

NOTE

NOTICE

Plug the input power cable of the unit to the wall outlet. The Power indicator will light up when 
the mains is normal. The Power indicator will turn off when there is a power failure. 

1. The master/slave function is disabled by default. Ensure that the master/slave function switch is 

on the disable status before operation.  

2. Only when the master/slave function is enabled, loads connected to slave outlets will be shut 

down after load is detected lower than 10 W in master outlet.  

3. Master/slave function operation

After connecting all devices to the unit, turn the master/slave function switch to the enable status. 
The slave on indicator will light up when the load connected to master outlet is above 30 W. 
Turn the master/slave function switch to the disable status, the function is disabled and the slave 
on indicator will be on. 

Summary of Contents for UPS2000-MBS-16A

Page 1: ...talling the unit ensure that the sum of the leakage currents of the unit and the devices it powers does not exceed 3 5 mA NOTICE 1 Slave outlets 2 Master outlets 3 Power indicator 4 Slave on indicator 5 Bypass switch 6 Outlet for UPS output 7 Outlet for UPS input 8 AC input 9 Circuit breaker 10 Master slave function switch Issue 01 Date 2016 03 25 UPS2000 MBS 16A PDU Maintenance Bypass Switch Modu...

Page 2: ... G 2KRTL when connecting UPS2000 G 1KRTL 1KRTS 2KRTS Refer to cable connection of UPS2000 G 3KRTL when connecting UPS2000 G 3KRTS 3 3 kVA UPS output form factor terminal or C20 varies with different actual models NOTE UPS2000 G 2KRTL UPS2000 G 3KRTL 2 Installing the Unit 3 Rack mounting Scenario Front Rear NOTICE When installing ensure that the PDU rear panel is aligned with the UPS rear panel C19...

Page 3: ...he mains is normal The Power indicator will turn off when there is a power failure 1 The master slave function is disabled by default Ensure that the master slave function switch is on the disable status before operation 2 Only when the master slave function is enabled loads connected to slave outlets will be shut down after load is detected lower than 10 W in master outlet 3 Master slave function...

Page 4: ...this time all connected devices are powered by the mains directly Turn off the UPS and disconnect two cables connected to the UPS Then you can maintain the UPS After maintaining the UPS ensure that the UPS operates properly Reconnect the UPS to the unit by following the installation section Verify that the Power indicator is on Turn on the UPS then transfer the rotary bypass switch from MBS to UPS...

Reviews: