Personal emergency signal functions
129
Putting into operation
7.
P
OSITION ALARM
sensor:
Position the radio set vertically. Wait for a short time.
Position the radio set horizontally. Wait for a short time.
The display changes to
OK
if the sensor passes the test.
The display shows the log-in status, e.g. "Secury - logged into Secury ser-
ver".
TIP
After completing the log-in, the radio set will react to all programmed emergency
signal functions and is constantly being monitored by the personal emergency signal
centre.
Fitting the tear-off cord
The tear-off cord is connected to the tear-off contact,
see section „Triggering the loss
alarm“ (p. 116). If the radio set detaches from your clothing or is forcefully torn off, the
tear-off cord is designed to open the tear-off contact and trigger a loss alarm.
Affix the free end of the tear-off cord to a suitable spot of your clothing near the radio
set. Ensure that the cord will neither be in your way as you work nor become a
hazard, e.g. by potentially coming into contact with rotating machine parts.
Affixing the radio set to your clothing
You should affix your radio set securely to your clothing directly after the sensor test.
To do this, use the clip or the bag.
Choose a suitable carrying position. Please bear in mind:
You must be able to reach all keys of your radio set reliably at any time.
The position alarm and the no-motion alarm must be reliably triggered in case of
an alarm.
The radio set must not come off your clothing by mistake.
TIP
While affixing the radio set, hold it vertically and do not move it too slowly in order to
avoid unintentionally triggering a position or no-motion alarm.
Summary of Contents for FT4
Page 1: ...TETRA Radio Set Funkwerk FT4 S Operating Manual...
Page 27: ......
Page 30: ...26 Conformity and approvals EC declaration of conformity...
Page 70: ...66 TETRA basics TETRA connection types...
Page 142: ...138 Personal emergency signal functions Shutting down...
Page 148: ...144 Technical data Side connector...
Page 149: ......