![FunkTronic Major 4 Manual Download Page 19](http://html1.mh-extra.com/html/funktronic/major-4/major-4_manual_2346432019.webp)
m4_eng(11.03.02)
- 19 -
Kompetent für Elektroniksysteme
039
Printer Parameters
1. digit
Print transmitted code
on/off --> 1/0
2. digit
Print received code
on/off --> 1/0
3. digit
Print within telephone mode
on/off --> 1/0
4. digit
Print transmitted conference calls
on/off --> 1/0
5. digit
Print received conference calls
on/off --> 1/0
040
1. digit
Bell tone volume for ordinary calls, 1 to 9
2. digit
Noise switch on/off --> 1/0
3. digit
Bell tone volume for emerqency calls, 1 to 9
4. digit
Automatic call transmission on/off --> 1/0
5. digit
PTT button blocking
0 = allways off
1 = on when carrier is detected
2 = off only after call or call detecting
041
1. digit
break after double sequence, n * 20 msec
2. digit
Blocking time for ID-code memory, n * 100 msec
3. digit
6th tone for ordinary calls
4. digit
Correlation module yes/no --> 2/0
5. digit
Carrier display, carrier input
0 = depenting on modulation, for 2-wire
1 = carrier input low
2 = carrier input high
3 = depenting on modulation, carrier input is
used for ext. PTT key
4 = depenting on modulation, carrier input is
used for ext. short call key
042
Automatic Loudspeaker Switch-Off
1. digit
0 = open mode
1 = selective mode
2. digit
0 = Loudspeaker remains off after put back handset
1 = Loudspeaker on after put back handset
3. digit
Loudspeaker timer hundreds
4. digit
Loudspeaker timer tens
5. digit
Loudspeaker timer ones
043
Keying tone Mode and frequency
1. digit
Mode
0 = Duplex
1 = Simplex
2. digit
Keying tone thousands
3. digit
Keying tone hundreds
4. digit
Keying tone tens
5. digit
Keying tone ones
044
Tone sequence setting
1. digit
2. digit
3. digit
Tone length 2. to 5. tone hundreds
4. digit
Tone length 2. to 5. tone tens
5. digit
Tone length 2. to 5. tone ones