- 18 -
Kompetent für Elektroniksysteme
034
Telephone Parameters
(only if equipped with telephone interface)
1. digit
n * 8 sec dial tone until cut-off
2. digit
0 = Pulse dialling
1 = DTMF dialling
3. digit
Single tone '0' ... 'D' for clear back
4. digit
Remote programming EEPROM 1 on/off --> 1/0
5. digit
Remote programming EEPROM 2 on/off --> 1/0
035
Scanner Parameters
1. digit
n * 20 ms dwelling time per channel
2. digit
Wait time after call (sec): tens
3. digit
Wait time after call (sec): ones
4. digit
Stop scanning if carrier on/off
5. digit
036
Scanner Parameters
1. digit
Scanner on/off
2. digit
Scanning up from channel: tens
3. digit
Scanning up from channel: ones
4. digit
Scanning up to channel:
tens
5. digit
Scanning up to channel:
ones
037
Telephone Parameters
(only if equipped with telephone interface)
1. digit
0 = Telephone mode off
1 = Manual telephone mode, telephone --> radio
2 = Automatic telephone mode with short call 0, telephone --> radio
3 = Telephone mode with touchtone dialling, telephone --> radio
2. digit Mode of TX keying
0 = Simplex mode, voice controlled
1 = Duplex mode, permanent
3. digit
n * 10 sec. TX time out without modulation
4. digit
n * 5 sec. TX time out in simplex mode
5. digit
(n + 1) * 60 sec. TX time out
038
Channel Parameters
1. digit
0 = No channel selection
1 = One digit channel selection
2 = Two digit channel selection
2. digit
1 = Channel output decimal
2 = Channel output binary-1
3 = Channel output binary
4 = Channel output 2 * BCD
5 = Channel remote control with keying tone/PTT
6 = Channel remote control without keying tone/PTT
3. digit
0 = Channel output ordinary
1 = Channel output inverted
4. digit
0 = Short channel display
1 = Permanent channel display
5. digit
0 = acknowledge for remote channel selection (K
1
K
2
K
3
XY)
1 = acknowledge for remote channel selection (K
2
K
1
K
3
XY)