background image

 

G E N E R A L   M A I N T E N A N C E  

 

1)  The blower motor is a sealed unit, 24,000 hr. MTBF rated.  It is permanently lubricated and does not require 

oiling – keep it free of dust accumulations to prevent overheating. 

2)  Remove any loose accumulations of dust/debris from the air filter chamber periodically. 

 
“This product employs overload protection (fuse). A blown fuse indicates an overload or short-circuit situation. If 

the fuse blows, unplug the product from the outlet. Replace the fuse as per the user servicing instructions (only 

10-Amp fuse) and check the product. If the replacement fuse blows, a short circuit may be present and the 

product should be discarded or returned to an authorized service facility for examination and/or repair”. 

 

Remote Interface and Connectivity Function 

The GS2-200 unit can be supplied with an optional interface package providing remote start/stop and filter 

monitoring capabilities (Part # FA228).  Please see instructions below for Relay Activation/De-Activation 

procedures and refer to the drawing in Figure 1 for remote connections.   

 

 

 

 

 

 

WARNING 

“To Prevent the Risk of Electrical Shock, Connect Remote Interface 

Cable to 24v, Class 2 Power Supply Only” 

 

 

 

 

 

WARNING 

“Disconnect From All Power Supplies Before Servicing” 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for GS2-200

Page 1: ...any solid state speed control device WARNING For general ventilating use only Do not use to exhaust hazardous or explosive materials or vapors WARNING Use only a 10 Amp fuse CAUTION Do not operate wit...

Page 2: ...o c a t i n g t h e a i r c l e a n e r Placing the GS2 200 unit as close as possible to the pollution source reduces the amount of ducting needed reduces back pressure lowers power consumption and im...

Page 3: ...Filter and then press the FILTER RESET button If the light remains illuminated or turns off and comes back on then contact Fumex for assistance The GS2 200 unit contains a VOC sensor to detect odors...

Page 4: ...s commonly found in industrial manufacturing processes Part FX4 Blend of FX1 with FX2 for broad spectrum gas treatment SELECTING GAS ODOR ADSORBENT FILTERS Media Selection and Service Life Fumex offer...

Page 5: ...tions only 10 Amp fuse and check the product If the replacement fuse blows a short circuit may be present and the product should be discarded or returned to an authorized service facility for examinat...

Page 6: ...returned PREPAID to Fumex LLC 1150 Cobb International Pl Kennesaw GA 30152 There are no warranties which extend beyond the descriptions set forth in this warranty notwithstanding any knowledge of Fume...

Page 7: ...flash drive with a configuration file and the USB port on the control board Contact Fumex to acquire the correct configuration file for your unit 8 Reprogram the software by changing the remoteSwitchO...

Page 8: ...ia a flash drive with a configuration file and the USB port on the control board Contact Fumex to acquire the correct configuration file for your unit 8 Reprogram the software by changing the remoteSw...

Page 9: ...9 DRAWINGS AND FIGURES Figure 1...

Page 10: ...10 DRAWINGS AND FIGURES Figure 2 Figure 3 ON OFF Relay Activation Switch...

Reviews: