GETTING STARTED
I n i t i a l s e t - u p
1. Open all cartons and locate inlet, hose, hose clamps and wheels. Refer to Table 1 for the applicable part
numbers for your model.
2. Remove ALL filters and packing materials from cartons and the unit cabinet.
3. Place the unit on its side and install wheels in the bottom plate.
4. Attach the inlet to the top of the lid with the six screws provided.
5. Remove plastic wrap from gas/odor filter (refer to Table 1 for filter part numbers).
6. Place gas/odor filter into the bottom of the cabinet and secure with the provided threaded rod, retaining plate,
and wingnuts (NOTE: Pay attention to direction of airflow arrow).
7. Place the FX7 pre-filter on top of the gas/odor filter.
8. Close and latch the lid.
9. Attach power cord to the power receptacle located on the lower rear of the cabinet.
L o c a t i n g t h e a i r c l e a n e r
Placing the GS2-200 unit as close as possible to the pollution source reduces the amount of ducting needed,
reduces back-pressure, lowers power consumption, and improves overall performance. Placement should
minimize hose length and the number of bends. Use capture hoods with high efficiency entry whenever
possible. The unit exhausts through the bottom panel make sure to allow for adequate ventilation.
I n l e t h o s e a t t a c h m e n t
The GS2-200 unit ships standard with a 1 x 2”, 2 x 2” or 1 x 3” inlet. Attach flex hose over the metal air inlet tube
and tighten securely with the stainless-steel clamp. Connect the hose to a Fumex suction hood or place as close
as possible to the pollution source.
E l e c t r i c p o w e r
GS2-200 series is manufactured with a universal blower/motor assembly (90-250/1/50-60) and must only use a 10-
Amp fuse. Default power cord/plug is US (120V). Contact Fumex for additional information or options.
Confirm that correct power supply is available.