FULTON FB-W 012 Installation And Operation Manual Download Page 26

© The Fulton Companies 2014

WARRANTY & PARTS

 

FBW-IOM-2014-0311 

SECTION 5

5-2

Standard Warranty for ICS/FB-A, ICW, ICX/FB-F, VMP, VMPW, FB-S, FB-L, FB-W, ICT

Eff ective Date: 2010-09-01 

Five (5) Year (60 Months) Material and Workmanship Warranty

The pressure vessel is covered against defective material or workmanship for a period of fi ve (5) years from the date of shipment from 
the factory. Fulton will repair or replace F.O.B. factory any part of the equipment, as defi ned above, provided this equipment has been 
installed, operated and maintained by the buyer in accordance with approved practices and recommendations made by Fulton. The 
commissioning agency must also successfully complete and return the equipment Installation and Operation Checklists to Fulton’s 
Quality Assurance department. This warranty covers any failure caused by defective material or workmanship; however, waterside 
corrosion or scaling is not covered. Therefore, it is imperative that the boiler water management and chemistry be maintained as 
outlined in the Installation and Operation Manual. 

Parts Warranty

Fulton will repair or replace F.O.B. factory any part of the equipment of our manufacture that is found to be defective in workmanship 
or material within one (1) year of shipment from the factory provided this equipment has been installed, operated and maintained by 
the buyer in accordance with approved practices and recommendations made by both Fulton and the component manufacturers and 
the commissioning agency has successfully completed and returned the equipment Installation and Operation Checklists to Fulton’s 
Quality Assurance department. 

General

Fulton shall be notifi ed in writing as soon as any defect becomes apparent. This warranty does not include freight, handling or labor 
charges of any kind. These warranties are contingent upon the proper sizing, installation, operation and maintenance of the boiler 
and peripheral components and equipment. Warranties valid only if installed, operated, and maintained as outlined in the Fulton 
Installation and Operation Manual. No Sales Manager or other representative of Fulton other than the Quality Manager or an offi

  cer of 

the company has warranty authority. Fulton will not pay any charges unless they were pre-approved, in writing, by the Fulton Quality 
Manager. This warranty is exclusive and in lieu of all other warranties, expressed or implied, including but not limited to the implied 
warranties of merchantability and fi tness for a particular purpose. Fulton shall in no event be liable for any consequential or incidental 
damages arising in any way, including but not limited to any loss of profi ts or business, even if the Fulton Companies has been advised 
of the possibility of such damages. Fulton’s liability shall never exceed the amount paid for the original equipment found to be 
defective. Excessive cycling will reduce the life of any boiler. Verifi cation that the system is properly designed and has been properly 
maintained to prevent excessive cycling may be required. To activate the warranty for this product, the appropriate commissioning 
sheets must be completed and returned to the Fulton Quality Assurance department for review and approval. 

Summary of Contents for FB-W 012

Page 1: ...INSTALLATIONAND OPERATIONMANUAL Electric HotWater Boiler FB W 12 to 700 kW 1 2 to 70 HP Serial National Board Model Fulton Order SoldTo Job Name Date FBW IOM 2014 0312...

Page 2: ......

Page 3: ...Control 2 5 STEPCONTROLLERS 2 5 WaterSupply 2 5 WATERQUALITY 2 5 WATERSPECIFICATION 2 5 ElectricalInstallation 2 7 MOTORS 2 7 ELECTRICELEMENTS 2 8 Operation 3 1 BeforeStartUp 3 2 Start Up 3 2 BoilerCo...

Page 4: ...TheFultonCompanies2014 TABLEOFCONTENTS FBW IOM 2014 0311 0 2...

Page 5: ...Questions Call 315 298 5121 orvisitusonlineat www fulton com 1 1 INTRODUCTION INTRODUCTION 1 INSTALLATION 2 OPERATION 3 MAINTENANCE 4 WARRANTY PARTS 5...

Page 6: ...otes in literature on stickers and labels and any additional safety precautions that apply Follow all safety codes and wear appropriate safety protection Follow all jurisdictional codes and consult an...

Page 7: ...Questions Call 315 298 5121 orvisitusonlineat www fulton com 2 1 INSTALLATION INTRODUCTION 1 INSTALLATION 2 OPERATION 3 MAINTENANCE 4 WARRANTY PARTS 5...

Page 8: ...h element This results in low flux temperatures and long element life Multiple vertically oriented stainless steel or Incolloy elements discourage build up because element expansion and contraction ca...

Page 9: ...UL requires at least 36 clear space be maintained in front of any electrical panel 3 Ensure all labels on the boiler will be fully visible for maintenance and inspection BoilerTrim Each boiler is sup...

Page 10: ...0 20 20 20 20 20 17 17 24 24 28 28 36 40 40 44 44 50 50 MM 508 508 508 508 508 508 432 432 610 610 711 711 914 1016 1016 1118 1118 1270 1270 H Overall Depth Electric Panel to Drain IN 34 34 34 34 34 3...

Page 11: ...s and dissolved minerals These materials may promote corrosion deposition and or fouling of equipment To prevent TABLE 1B SPECIFICATIONS Model FB W 012 015 018 024 030 036 050 070 105 140 175 210 280...

Page 12: ...per less than 25 ppm Corrosion Inhibitor level capable of maintaining iron corrosion rates 2 mpy Due to changing environmental restrictions a non heavy metal all organic inhibitor is recommended which...

Page 13: ...ect wiring as shown in wiring diagram which is furnished inside the electrical control panel Be sure to install a fused switch for the contactors and a separate fused switch for the circulating pump s...

Page 14: ...c elements will have an increase in watt density if the applied voltage is higher than the element design voltage Therefore electric elements have a 0 tolerance for operation over design voltage Elect...

Page 15: ...Questions Call 315 298 5121 orvisitusonlineat www fulton com 3 1 OPERATION INTRODUCTION 1 INSTALLATION 2 OPERATION 3 MAINTENANCE 4 WARRANTY PARTS 5...

Page 16: ...ter level is too low A low water cut off condition will require pushing the manual reset button on the panel box Water Relief Valve ASME Approved releases extra pressure Water Outlet Valve allows wate...

Page 17: ...he fused switch that controls the circulating pump should be kept in the on position at all times during the boiler operation as well as during the non operating period of the boiler This should be tu...

Page 18: ...conduct and strict adherence to applicable jurisdictional professional codes and regulations Failure to follow instructions may result in a fire or explosion causing property damage personal injury o...

Page 19: ...Questions Call 315 298 5121 orvisitusonlineat www fulton com 4 1 MAINTENANCE INTRODUCTION 1 INSTALLATION 2 OPERATION 3 MAINTENANCE 4 WARRANTY PARTS 5...

Page 20: ...section of the manual DailyMaintenanceandInspectionSchedule Daily maintenance and inspection must include the following 1 Check all valves for proper opening and closing 2 Check supply water pump for...

Page 21: ...oroughly clean the surface on boiler and on plate 2 Place neoprene gasket on handhole plate Be sure the gasket is pushed down tight on the plate Do not use any grease lubricant or adhesive 3 After pla...

Page 22: ...verify power in each stage or that component is supplied 2 If part of the voltage is stopped at any point replace that component and continue the test until all circuits test clear Control Switch Fail...

Page 23: ...ff an ohm meter can be used to check the contactor points between the contac tor supply and contactor feed to verify the contactor is pulling in A visual inspection on the side of the contactor can be...

Page 24: ...TheFultonCompanies2014 MAINTENANCE FBW IOM 2014 0311 SECTION4 4 6...

Page 25: ...Questions Call 315 298 5121 orvisitusonlineat www fulton com 5 1 WARRANTY PARTS INTRODUCTION 1 INSTALLATION 2 OPERATION 3 MAINTENANCE 4 WARRANTY PARTS 5...

Page 26: ...lly completed and returned the equipment Installation and Operation Checklists to Fulton s Quality Assurance department General Fulton shall be notified in writing as soon as any defect becomes appare...

Page 27: ...nd system performance and voids the product warranty Parts Spare and replacement parts may be ordered from your local representative or through the Fulton Companies When ordering replacement parts ple...

Page 28: ...TheFultonCompanies2014 WARRANTY PARTS FBW IOM 2014 0311 SECTION5 5 4 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 29: ...Questions Call 315 298 5121 orvisitusonlineat www fulton com SECTION5 FBW IOM 2014 0311 WARRANTY PARTS 5 5 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 30: ...TheFultonCompanies2014 WARRANTY PARTS FBW IOM 2014 0311 SECTION5 5 6...

Page 31: ......

Page 32: ...nstallation Operation and Maintenance manual may be reproduced in any form or by any means without permission in writing from the Fulton Companies Fulton BoilerWorks Inc Fulton Heating Solutions Inc F...

Reviews: