- (HU01 - 03) -
Hydraulic unit / 3 phase
H
YD
R
A
U
LI
C U
N
IT
WS
K1
60
D
C
9
H
YD
R
A
U
LI
C U
N
IT
WS
K1
60
D
C
9
SPECIFICATIONS
22
TECHNICAL SPECIFICATIONS
2-12
Model name (Hydraulic unit)
WS
Û
K160DC9
Model name (Outdoor unit)
WO
Û
K112LCT
WO
Û
K140LCT
WO
Û
K160LCT
Input power
Enclosure
Heating
Rated
kW
0.08
Max. *1
9
Casing
Colour
WHITE
Material
8/10mm DC01 + EZ (5µ)
Dimensions
(H x W x D)
Net
mm
800 x 450 x 457
Gross
955 x 550 x 530
Weight
Net
kg
42
Gross
48
Main components
Pump
Type
Water cooled
Speed setting
Variable pressure / Constant pressure
Input power
W
70 *2
Water side
Heat
exchanger
Type
Double-tube
Q’ty
1
Water volume
l
16
Water flow
rate Min.
l/h
1200
1500
1700
Water flow
rate Nom.
Heating
l/h
1891
2357
2639
Cooling
1902
Insulation material
polyurethane
Expansion
vessel
Volume
l
8
Max. water
pressure
bar
4.5
Pre pressure
1 bar (+/-20%)
Water circuit
Piping connections diameter
mm
ø25.4(ø1 in.)
Piping
ø25.4(ø1 in.)
Safety valve
bar
3
Manometer
Yes
Drain valve / Fill valve
Yes
Air purge valve
Yes
Connection pipe
(Refrigerant circuit)
Liquid side diameter
mm
ø9.52(ø3/8 in.)
Gas side diameter
ø15.88(ø5/8 in.)
Method
Flare
Sound pressure level
Heating
dBA
39
Operation range
Waterside
Heating
°C
8 to 60
Pump rank
A
*1: With electric back-up heater.
*2: The value is at Full speed and full flow.