- (CS01 - 14) -
Control system
- (CS01 - 14) -
C
O
N
TR
O
L
SY
ST
EM
C
O
N
TR
O
L
SY
ST
EM
LINE
ACCESS
LEVEL
FUNCTION
SETTING RANGE
OR DISPLAY
FACTORY
SETTING
Swimming pool
2056
U
Setpoint source heating
8.0…80.0°C
22.0°C
Heat pump
2803
S
Overrun time cond pump
0…240s
240s
2843
S
Compressor off time min
0…120min
8min
2844
S
Switch-off temp max
8…100°C
75°C
2862
S
Locking time stage 2
0…40min
5min
2873
S
Compressor mod run time
10…240s
240s
2882
S
Release integral electric flow
0…500°Cmin
100°Cmin
2884
S
Release electric flow below OT
---, -30…30°C
2°C
2886
S
Compensation heat deficit
Off
On
Only with
floor curing fct
Off
2916
S
Max setpoint HP DHW charg
---, 8… 80°C
60°C
2920
S
With electrical utility lock
Locked / Release
Released
Supplementary source
3700
S
Release below outside temp
---, -50…50°C
2.0°C
3701
S
Release above outside temp
---, -50…50°C
3705
S
Overrun time
0...120min
20min
3720
S
Switching integral (for boiler relief)
0...500°Cmin
100°Cmin
3723
Locking time
0...120min
30min
DHW storage tank
5024
S
Switching differential
0…20°C
7°C
5030
S
Charging time limitation
---, 10…600min
90min
5055
S
Recooling temp
8…95°C
65°C
5057
S
Recooling collector
Off
Summer
Always
Summer
5061
S
Electric immersion heater release
24h/day
DHW release
Time program 4/DHW
DHW release
5093
S
Not used