Detecting and Managing Faults
41
Note –
The system can boot and run using memory that was not disabled.
Related Information
■
“Clear POST-Detected Faults” on page 41
■
“Examples of POST Management” on page 37
■
“POST Output Quick Reference” on page 42
▼
Clear POST-Detected Faults
In most cases, when POST detects a faulty component, POST logs the fault and
automatically takes the failed component out of operation by placing the component
in the ASR blacklist. See
“Managing Components With Automatic System Recovery
In most cases, the replacement of the faulty FRU is detected when the service
processor is reset or power cycled. In this case, the fault is automatically cleared from
the system. This procedure describes how to identify a POST detected fault and, if
necessary, manually clear the fault.
1. After replacing a faulty FRU, enter the
show faulty
command to identify any
faults detected by POST.
POST-detected faults are distinguished by the text
Forced fail
. No UUID
number is reported for POST-detected. The following example shows
show
faulty
output for a failed memory module in FB-DIMM slot
/SYS/MB/CMP0/BR1/CMP0/D0.
If no fault is reported, this procedure is complete. Do not perform the subsequent
steps.
->
show faulty
Target | Property | Value
----------------------+------------------------+-----------------------------
/SP/faultmgmt/0 | fru | /SYS/MB/CMP0/BR1/CH0/D0
/SP/faultmgmt/0 | timestamp | Dec 21 16:40:56
/SP/faultmgmt/0/ | timestamp | Dec 21 16:40:56
faults/0 | |
/SP/faultmgmt/0/ | sp_detected_fault | /SYS/MB/CMP0/BR1/CH0/D0
faults/0 | | Forced fail(POST)
Summary of Contents for SPARC Enterprise T5120
Page 1: ......
Page 2: ......
Page 6: ......
Page 82: ...56 SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009 ...
Page 200: ...174 SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009 ...
Page 234: ...208 SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009 ...
Page 239: ......
Page 240: ......