Chapter 3
Troubleshooting
3-17
3.5.4.2
fmdump -e
Command
To get information of the errors that caused this failure you can use the -e option, as
shown in the following example.
3.5.5
Using the
fmadm
Command
3.5.5.1
Using the
fmadm faulty
Command
The fmadm faulty command can be used by administrators and service personnel to
view and modify system configuration parameters that are maintained by the Oracle
Solaris Fault Manager. The command is primarily used to determine the status of a
component involved in a fault, as shown in the following example:
The PCIe slot has been degraded and it is associated with the same UUID as above.
Also, the "faulted" status may be displayed.
#
fmdump -e
TIME CLASS
Nov 02 10:04:14.3008 ereport.io.fire.jbc.mb_per
#
fmadm faulty
STATERESOURCE / UUID
-------- --------------------------------------------------------
degraded dev:////pci@1e,600000
0ee65618-2218-4997-c0dc-b5c410ed8ec2
#
fmadm repair
0ee65618-2218-4997-c0dc-b5c410ed8ec2
Summary of Contents for SPARC Enterprise M3000
Page 4: ......
Page 91: ...Chapter 5 Internal Components Access 5 5 FIGURE 5 3 Removing the Air Duct ...
Page 114: ...7 10 SPARC Enterprise M3000 Server Service Manual March 2012 ...
Page 120: ...8 6 SPARC Enterprise M3000 Server Service Manual March 2012 ...
Page 128: ...9 8 SPARC Enterprise M3000 Server Service Manual March 2012 ...
Page 146: ...12 6 SPARC Enterprise M3000 Server Service Manual March 2012 ...
Page 152: ...13 6 SPARC Enterprise M3000 Server Service Manual March 2012 ...
Page 160: ...14 8 SPARC Enterprise M3000 Server Service Manual March 2012 ...
Page 166: ...15 6 SPARC Enterprise M3000 Server Service Manual March 2012 ...
Page 170: ...A 4 SPARC Enterprise M3000 Server Service Manual March 2012 ...
Page 178: ...B 8 SPARC Enterprise M3000 Server Service Manual March 2012 ...