2-10
SPARC Enterprise M3000 Server Service Manual • March 2012
TABLE 2-4
State Display by Combination of LEDs on the Operator Panel
Name
Description
POWER
*
* READY LED is referred to when the XSCF unit status is indicated.
XSCF STANDBY
CHECK
XSCF
Off
Off
Off
Power is not being supplied.
Off
Off
On
Power has been turned on.
Off
Blinking
Off
The XSCF unit is being initialized.
Off
Blinking
On
An error occurred in the XSCF unit.
Off
On
Off
The XSCF unit is in the standby state.
The server is waiting for power-on of the air
conditioning facilities in the data center.
On
On
Off
Warm-up standby processing is in progress (power is
turned on after the end of processing).
The power-on sequence is in progress.
The server is in operation.
Blinking
On
Off
The power-off sequence is in progress.
(The fan units are stopped after the end of processing.)
Summary of Contents for SPARC Enterprise M3000
Page 4: ......
Page 91: ...Chapter 5 Internal Components Access 5 5 FIGURE 5 3 Removing the Air Duct ...
Page 114: ...7 10 SPARC Enterprise M3000 Server Service Manual March 2012 ...
Page 120: ...8 6 SPARC Enterprise M3000 Server Service Manual March 2012 ...
Page 128: ...9 8 SPARC Enterprise M3000 Server Service Manual March 2012 ...
Page 146: ...12 6 SPARC Enterprise M3000 Server Service Manual March 2012 ...
Page 152: ...13 6 SPARC Enterprise M3000 Server Service Manual March 2012 ...
Page 160: ...14 8 SPARC Enterprise M3000 Server Service Manual March 2012 ...
Page 166: ...15 6 SPARC Enterprise M3000 Server Service Manual March 2012 ...
Page 170: ...A 4 SPARC Enterprise M3000 Server Service Manual March 2012 ...
Page 178: ...B 8 SPARC Enterprise M3000 Server Service Manual March 2012 ...