Chapter 3
Troubleshooting
3-7
3.3.2.1
Checking the Software Configuration
The following procedure can be used to check the software configuration from the
domain console.
●
Type
showrev
.
The
showrev
command displays system configuration information on the screen.
3.3.2.2
Checking the Firmware Configuration
Login authority is required to check the firmware configuration. The procedure
below can be used to check the configuration from the maintenance terminal.
1. Log in with the account of the XSCF hardware field engineer.
2. Type
version
.
The
version
command displays firmware version information on the screen. For
details, see the
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF
User's Guide
.
3.3.2.3
Downloading Error Log Information
To download error log information, use the XSCF log fetch function. The XSCF unit
has an interface with external units so that the authorized service personnel can
easily obtain useful maintenance information such as error logs.
Connect the maintenance terminal, and use the XSCF Shell or XSCF Web to
download error log information to the maintenance terminal.
#
showrev
XSCF>
version
Summary of Contents for SPARC Enterprise M3000
Page 4: ......
Page 91: ...Chapter 5 Internal Components Access 5 5 FIGURE 5 3 Removing the Air Duct ...
Page 114: ...7 10 SPARC Enterprise M3000 Server Service Manual March 2012 ...
Page 120: ...8 6 SPARC Enterprise M3000 Server Service Manual March 2012 ...
Page 128: ...9 8 SPARC Enterprise M3000 Server Service Manual March 2012 ...
Page 146: ...12 6 SPARC Enterprise M3000 Server Service Manual March 2012 ...
Page 152: ...13 6 SPARC Enterprise M3000 Server Service Manual March 2012 ...
Page 160: ...14 8 SPARC Enterprise M3000 Server Service Manual March 2012 ...
Page 166: ...15 6 SPARC Enterprise M3000 Server Service Manual March 2012 ...
Page 170: ...A 4 SPARC Enterprise M3000 Server Service Manual March 2012 ...
Page 178: ...B 8 SPARC Enterprise M3000 Server Service Manual March 2012 ...