TX2540 M1
Operating Manual
91
Troubleshooting and tips
8.9
Added drive reported as defective
RAID controller is not configured for this drive
The drive was probably installed when the system was switched off.
Ê
Reconfigure the RAID controller for the drive using the corresponding utility.
Information is provided in the documentation for the RAID controller.
or
Ê
Remove and reinstall the drive while the system is switched ON.
If the hard disk drive continues to be shown as defective, then replace it (see
the "FUJITSU Server PRIMERGY TX2540 M1 Server Upgrade and
Maintenance Manual").
I
Further information is provided in the "Integrated RAID for SAS User’s
Guide" (on the ServerView Suite DVD under
Industry Standard Servers
-
Expansion Cards
-
Storage Adapters
-
LSI RAID / SCSI Controllers
) or in the
"Modular RAID Controller Installation Guide" (on the ServerView Suite
DVD under
Industry Standard Servers
-
Expansion Cards
-
Storage Adapters
-
LSI RAID / SCSI Controllers
).
For more information on configuring the controller, see section
"Configuring the server" on page 80
.
8.10 Error message on screen
The meaning of the error message is explained in the documentation for the
relevant components and programs on the Fujitsu manuals server.
8.11
Expansion cards or onboard devices not
recognized
When an expansion card is added, other expansion cards or onboard devices
might not be recognized.
Ê
Reinstall the drivers for the expansion cards or onboard devices that are not
recognized.
Summary of Contents for PRIMERGY TX2540 M1
Page 6: ...Operating Manual TX2540 M1 ...
Page 10: ...Operating Manual TX2540 M1 Contents ...
Page 14: ...14 Operating Manual TX2540 M1 Introduction ...
Page 34: ...34 Operating Manual TX2540 M1 Functional overview ...
Page 62: ...62 Operating Manual TX2540 M1 Hardware installation ...
Page 86: ...86 Operating Manual TX2540 M1 Property and data protection ...