15.2.4 Acoustic indicators
PEI Beep Codes
Pre-EFI Initialization (PEI) - memory Initialization (bootblock)
DXE Beep Codes
Driver Execution Environment (DXE) - main hardware Initialization (POST)
# of
Beep
Description
Action
1
Memory not installed
Ê
Check if the memory module is installed.
Ê
Check if the memory module is installed
correctly.
2
Recovery started
Recovery procedure is initialized by jumper
settings on the system board and announced
with two beep.
This is only an information.
4
Recovery failed
Ê
Restart the recovery procedure again.
Ê
If the same beep code sounds again,
replace the system board.
# of
Beep
Description
Action
1
Invalid password
Ê
Check for the correct password and try
again.
Ensure that the caps lock key is
deactivated.
5
No Console Input
devices1 or Output
devices2 are found
Booting will continue.
1 Serial console redirection is considered a
console output device if enabled.
2 Serial console redirection is considered a
console input device if enabled.
This beep code is only an information.
Summary of Contents for PRIMERGY TX1320 M4
Page 20: ...Upgrade and Maintenance Manual TX1320 M4 Contents ...
Page 32: ...32 Upgrade and Maintenance Manual TX1320 M4 Before you start ...
Page 46: ...46 Upgrade and Maintenance Manual TX1320 M4 Important information ...
Page 96: ...96 Upgrade and Maintenance Manual TX1320 M4 Basic software procedures ...
Page 128: ...128 Upgrade and Maintenance Manual TX1320 M4 Power supply unit PSU ...
Page 216: ...216 Upgrade and Maintenance Manual TX1320 M4 Main memory ...
Page 260: ...260 Upgrade and Maintenance Manual TX1320 M4 Accessible drives ...
Page 312: ...312 Upgrade and Maintenance Manual TX1320 M4 System board and components ...
Page 340: ...340 Upgrade and Maintenance Manual TX1320 M4 Appendix A ...
Page 342: ...342 Upgrade and Maintenance Manual TX1320 M4 Appendix B ...
Page 367: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...