232
Upgrade and Maintenance Manual
TX1320 M4
Processor (CPU)
11.3
Replacing the heat sink
11.3.1 Preliminary steps
Ê
"Locating the defective server" on page 47
Ê
"Shutting down the server" on page 49
Ê
"Disconnecting the power cord" on page 50
Ê
"Getting access to the component" on page 51
11.3.2 Removing the defective heat sink
Ê
Remove the heat sink, see section
"Removing the heat sink variant 1" on
"Removing the heat sink variant 2" on page 220
.
Ê
Remove the residual thermal paste from the CPU surface.
Ê
Clean the CPU surface using a lint-free cloth.
11.3.3 Installing the new heat sink
Ê
Remove the protective cover on the underside of the new heat sink.
V
CAUTION!
Do not touch the thermal paste on the underside of the heat sink.
Ê
Install the heat sink, see section
"Installing the heat sink variant 1" on
"Installing the heat sink variant 2" on page 230
.
Field Replaceable Unit
(FRU)
Hardware: 15 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver
Summary of Contents for PRIMERGY TX1320 M4
Page 20: ...Upgrade and Maintenance Manual TX1320 M4 Contents ...
Page 32: ...32 Upgrade and Maintenance Manual TX1320 M4 Before you start ...
Page 46: ...46 Upgrade and Maintenance Manual TX1320 M4 Important information ...
Page 96: ...96 Upgrade and Maintenance Manual TX1320 M4 Basic software procedures ...
Page 128: ...128 Upgrade and Maintenance Manual TX1320 M4 Power supply unit PSU ...
Page 216: ...216 Upgrade and Maintenance Manual TX1320 M4 Main memory ...
Page 260: ...260 Upgrade and Maintenance Manual TX1320 M4 Accessible drives ...
Page 312: ...312 Upgrade and Maintenance Manual TX1320 M4 System board and components ...
Page 340: ...340 Upgrade and Maintenance Manual TX1320 M4 Appendix A ...
Page 342: ...342 Upgrade and Maintenance Manual TX1320 M4 Appendix B ...
Page 367: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...