Accessible drives
V
CAUTION!
Observe the safety instructions in the
chapter “Safety notes” on page 11
et seq. .
7.1
Installing an accessible 5.25-inch drive
One 5.25-inch bay is available for accessible drives. The 5.25-inch drives
available are DVD-ROM, DVD-RW and tape drives. These drives can be
installed in the free 5.25-inch bay.
I
For installing a tape drive you need an additional SCSI controller
because there is no onboard SCSI controller on the system board.
Ê
Open the server as described in the
chapter “Preparation” on page 17
et
seq. .
Figure 18: Removing the dummy cover
Ê
Press the two locking levers of the dummy cover in direction of the arrows
and pull the dummy cover out of the bay.
V
CAUTION!
Keep the dummy cover for future use. If you remove the accessible drive
again and do not replace it with a new one, the dummy cover must be
reinstalled to comply with EMC regulations and to satisfy cooling require-
ments and fire protection measures.