Starting up and operation
I
Depending on the settings in the BIOS, the standard LAN port 1 may also
be used as a management LAN port. You will find further information in
the "D3289 BIOS Setup Utility for FUJITSU Server PRIMERGY TX2560
M1 / RX2560 M1 Reference Manual".
7
Global Error
indicator
Global Error indicator (yellow) on the system board,
visible through the chassis perforation.
–
Lights up yellow
if a prefailure event has been
detected that requires (precautionary) service
intervention.
–
Flashes yellow
if an error was detected that requires
service intervention.
–
Does not light up
if there is no critical event.
If the event is still acute after a power cycle, the indicator
is activated after the restart.
The indicator also lights up in standby mode.
You can find more details on the indicated errors in the
System Event Log (SEL), in the ServerView Operations
Manager or via the iRMC S4's Web interface.