Starting up and operation
Solid state disk indicators
Figure 11: Indicators on the SSD modules
1 LED
green
BUSY (green)
– Lights up: SSD in active phase
– Does not light: SSD inactive (drive inactive)
2 LED
orange
FAULT (orange)
(in conjunction with a RAID controller)
– Does not light: no error
– Lights up: Faulty or Rebuild Stopped (drive defective/needs
replacing, a rebuild process was stopped or the module is not
correctly inserted)
– Slow flashing: Rebuild (the data is being restored after
changing a drive)
– Fast flashing: Identify