RX2530 M4
Upgrade and Maintenance Manual
203
Expansion cards and backup units
Figure 113: Numbering riser modules
I
Note for slot 4 in a 3.5-inch HDD chassis
If an FBU will be installed in a 3.5-inch HDD chassis, slot 4 cannot be
equipped with an expansion card.
I
As an option a full height riser module can be installed, see section
"Upgrading to the full height riser module" on page 249
. In this case the
slot 3 is not available and slot 4 can be equipped with a full height
expansion card.
No.
Riser module Slot offered Type
Description
1
Riser module 1 Slot 1
PCIe Gen3 x8
Low-profile slot, maximum length
167.65 mm (6.6 inch); dedicated
slot for modular RAID controller
Slot 2
PCIe Gen3 x16
Low-profile slot, maximum length
167.65 mm (6.6 inch)
2
Riser module 2 Slot 3
PCIe Gen3 x16
Low-profile slot, maximum length
167.65 mm (6.6 inch)
3
Riser module 3 Slot 4
PCIe Gen3 x16
(CPU2)
Low-profile slot, maximum length
167.65 mm (6.6 inch)
Summary of Contents for PRIMERGY RX2530 M4
Page 22: ...Upgrade and Maintenance Manual RX2530 M4 Contents ...
Page 34: ...34 Upgrade and Maintenance Manual RX2530 M4 Before you start ...
Page 108: ...108 Upgrade and Maintenance Manual RX2530 M4 Basic software procedures ...
Page 128: ...128 Upgrade and Maintenance Manual RX2530 M4 Power supply unit PSU ...
Page 192: ...192 Upgrade and Maintenance Manual RX2530 M4 Hard disk drive HDD solid state drive SSD ...
Page 200: ...200 Upgrade and Maintenance Manual RX2530 M4 Fans ...
Page 358: ...358 Upgrade and Maintenance Manual RX2530 M4 Front panel ...
Page 436: ...436 Upgrade and Maintenance Manual RX2530 M4 Appendix A ...
Page 438: ...438 Upgrade and Maintenance Manual RX2530 M4 Appendix B ...
Page 465: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...