Fans
8.1
Basic information
Base units are supplied with four hot-plug fan modules (1 CPU configuration) or
eight hot-plug fan modules (2 CPU configuration).
Base units with four fan modules operate in a 1 of 4 redundancy, base units with
eight fan modules operate in a 1 of 8 redundancy. In other words, if one of the
four or eight fan modules fails, the system will operate without any problem. The
failed fan module can be exchanged without shutting down the server (hot-
plug).
V
CAUTION!
Depending on the CPU type and heat sink type, different fan types are
necessary!
Ê
Please check, if you ordered the correct fans, see figure
.
I
Fan type A3C40201803 is a single rotor fan, fan type A3C40201802 is a
dual rotor fan. In the system information (Chassis ID EPROM) the terms
"Single Fan" and "Dual Fan" are used in system names.
Summary of Contents for PRIMERGY RX2530 M4
Page 22: ...Upgrade and Maintenance Manual RX2530 M4 Contents ...
Page 34: ...34 Upgrade and Maintenance Manual RX2530 M4 Before you start ...
Page 108: ...108 Upgrade and Maintenance Manual RX2530 M4 Basic software procedures ...
Page 128: ...128 Upgrade and Maintenance Manual RX2530 M4 Power supply unit PSU ...
Page 192: ...192 Upgrade and Maintenance Manual RX2530 M4 Hard disk drive HDD solid state drive SSD ...
Page 200: ...200 Upgrade and Maintenance Manual RX2530 M4 Fans ...
Page 358: ...358 Upgrade and Maintenance Manual RX2530 M4 Front panel ...
Page 436: ...436 Upgrade and Maintenance Manual RX2530 M4 Appendix A ...
Page 438: ...438 Upgrade and Maintenance Manual RX2530 M4 Appendix B ...
Page 465: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...