84
Operating Manual
RX2530 M1
Troubleshooting and tips
8.6
Incorrect date and time
Ê
Set the date and time in the operating system or in the BIOS Setup under
the
Main
menu, using
System Date
and
System Time
respectively.
I
Note that the operating system may affect the system time. For example,
the operating system time may deviate from the system time under
Linux, and would overwrite the system time in the default setting on
shutdown.
If the date and time are still wrong after the server has been switched off and
back on again, replace the lithium battery (for a description refer to the
"FUJITSU Server PRIMERGY RX2530 M1 Upgrade and Maintenance
Manual") or contact our customer service team.
8.7
System will not boot
The system will not boot after installing a new hard disk drive.
SAS configuration incorrect
Ê
Check the settings for the hard disk drives (
SAS Device Configuration
) and the
additional settings in the SAS configuration menu.
8.8
Drives reported as “dead” when starting
system
This error message can occur when the onboard SAS controller has RAID
functionality or the server is equipped with a PCI RAID controller.
RAID controller configuration incorrect
Ê
Check and correct the settings for the drives using the RAID controller utility.
Further information is provided in the manual for the RAID controller.
Summary of Contents for PRIMERGY RX2530 M1
Page 6: ...Operating Manual RX2530 M1 ...
Page 10: ...Operating Manual RX2530 M1 Contents ...
Page 30: ...30 Operating Manual RX2530 M1 Functional overview ...
Page 46: ...46 Operating Manual RX2530 M1 Important information ...
Page 58: ...58 Operating Manual RX2530 M1 Hardware installation ...
Page 80: ...80 Operating Manual RX2530 M1 Property and data protection ...