99
PRIMERGY BX600 S3 Blade Server System Unit Hardware Guide
6.5.2 Messages Displayed When a Non-durable
Components Life has been Reached
■
The flow of the replacement period notice
■
Messages displayed when the replacement period for non-durable
components has been reached
●
Prior notice
When one year operation time remains until the end of the life time, a notification is sent via Web UI of
a Management Blade.
• Status Display ("Power Supply Live Time Counter" in [System Property] - [Environ./Maintenance] -
[Power Supply]) changes the status from "Healthy". And the message (blue) prompts to contact an
office listed in the "Contact Information" of "Start Guide".
• Eventlog ([System Property] - [System Eventlog]) keeps a record that the remaining life time is one
year.
The remaining time and the days displayed on a log are not correct. Check for the correct time in the
[Power Supply Live Time Counter] in the status display.
• The display in "Fan Units" or "Power Supply Units" in the main window changes from "ok" to
"ok(Pre-Expiry)".
●
Life time notice
When operation time has exceeded the projected life time, a notification is sent via as Web UI of a
Management Blade.
• Status Display ("Power Supply Live Time Counter" in [System Property] - [Environ./Maintenance] -
[Power Supply]) shows the message (red) prompts to contact an office listed in the "Contact
Information" of "Start Guide".
• Eventlog ([System Property] - [System Eventlog]) keeps a record that the life time has been
exceeded.
• The display in "Fan Units" or "Power Supply Units" in the main window changes from "ok" to
"ok (Expiry)".
Normal status
Life time notice
Contact a maintenance
support office and
check the
"Contact Check Box" (*)
Prior notice
Replace
non-durable
components
1 year of operation
time remaining
Click [Reset]
Component has exceeded
the projected lifetime
*: Display [System Property] - [Environ./Maintenance] - [Power Supply] via Web UI of
a Management Blade, and check the applicable box in "Power Supply Live Time Counter".
If the box is checked, it can only be unchecked by clicking [Reset].
Summary of Contents for PRIMERGY BX600 S3
Page 18: ...18 Chapter 2 Security ...