Installing the rack server
Installation
A26361-K632-Z100-1-7619
25
Connecting the server to the line voltage
The server can be equipped with a permanently installed power supply (standard) or with a plug-in
power supply (hot plug) consisting of one or two modules. With two power supply modules the
server is equipped with a redundant power supply. If a defect occurs in one module, the respective
other module ensures unimpaired further operation. The defective module can be replaced during
operation.
Standard power supply
The power supply of the server can be set to the following line voltage range:
100 V to 125 V or 200 V to 240 V.
!
Before connecting the server to the line voltage, you must always check that the line
voltage range set on the server corresponds to the local line voltage. The marker arrow on
the plug-in unit points to the voltage range set.
100 V - 125 V
200 V - 240 V
a
Ê
If the wrong line voltage is set, lift out the plug-in unit with a screwdriver (a), turn it and replace
it.
1
2
Ê
Plug the power cable of the server into the server (1) and into a free electrical outlet of the
multi-outlet assembly in the rack (2) (see technical manual for rack).