Interface
Table 5.10 Features Field values (subcommands) and functions (1/3)
Features Field
Function
X’D0’
SMART READ DATE:
A device that received this subcommand saves all the updated attribute
values. The device then transfers 512-byte attribute value information to the
host after transferring PIOSU.
* For information about the format of the attribute value information, see
Table 5.11.
X’D1’
SMART READ ATTRIBUTE THRESHOLDS:
This subcommand is used to transfer 512-byte guarantee failure threshold
value data to the host.
* For information about the format of the guarantee failure threshold value
data, see Table 5.12.
X’D2’
SMART ENABLE/DISABLE ATTRIBUTE AUTOSAVE:
Enables (by setting the Sector Count field to a value other than 00h) or disables
(by setting the Sector Count field to 00h) a function that automatically saves
device attribute values (“automatic attribute save function”). This setting is
held regardless of whether the device is turned on or off. If the automatic
attribute save function is enabled and more than 15 minutes has elapsed since
the last time that attributes were saved, then the attributes are saved.
However, if the automatic attribute save function is disabled, the attributes
are not saved. Upon receiving this subcommand, a device enables or
disables the automatic attribute save function, and transfers the RegDH, then
reports the status.
In this drive, this function is enabled at the shipment from the factory.
X’D3’
SMART SAVE ATTRIBUTE VALUES:
When the device receives this subcommand, if saves device attribute value
data, and transfers the RegDH, then reports the status.
X’D4’
SMART EXECUTIVE OFF-LINE IMMEDIATE:
A device which receives this command starts collecting the off-line data
specified in the Sector Number field, or stops.
In the off-line mode, after transferring the RegDH, off-line data are
collected. In the captive mode, it collects off-line data then transfers the
RegDH when collection of data is completed.
SN Off-line data collection mode
00h: Off-line diagnosis (off-line mode)
01h: Simple self-test (off-line mode)
02h: Comprehensive self-test (off-line mode)
03h: Conveyance self-test (off-line mode)
04h: Selective self-test (off-line mode)
7Fh: Self-test stop
81h: Simple self-test (captive mode)
82h: Comprehensive self-test (captive mode)
83h: Conveyance self-test (captive mode)
84h: Selective self-test (captive mode)
5-56
C141-E249
Summary of Contents for MHW2040BS
Page 1: ...C141 E249 01EN MHW2120BS MHW2100BS MHW2080BS MHW2060BS MHW2040BS DISK DRIVES PRODUCT MANUAL ...
Page 4: ...This page is intentionally left blank ...
Page 8: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 42: ...This page is intentionally left blank ...
Page 54: ...This page is intentionally left blank ...
Page 74: ...This page is intentionally left blank ...
Page 86: ...Interface Figure 5 2 Example of the circuit for driving Ready LED 5 12 C141 E249 ...
Page 256: ...This page is intentionally left blank ...
Page 278: ...This page is intentionally left blank ...
Page 282: ...This page is intentionally left blank ...
Page 284: ...This page is intentionally left blank ...
Page 292: ...This page is intentionally left blank ...
Page 294: ......
Page 295: ......
Page 296: ......