4.7 Servo Control
C141-E120-02EN
4-21
(1) Write/read recovery
This area is used to absorb the write/read transient and to stabilize the AGC.
(2) Servo mark
This area generates a timing for demodulating the gray code and position-
demodulating the servo A to D by detecting the servo mark.
(3) Gray code (including index bit)
This area is used as cylinder address. The data in this area is converted into the
binary data by the gray code demodulation circuit
(4) Servo A, servo B, servo C, servo D
This area is used as position signals between tracks and the IDD control at on-
track so that servo A level equals to servo B level.
(5) PAD
This area is used as a gap between servo and data.
4.7.4 Actuator motor control
The voice coil motor (VCM) is controlled by feeding back the servo data recorded
on the data surface. The MPU fetches the position sense data on the servo frame
at a constant interval of sampling time, executes calculation, and updates the
VCM drive current.
The servo control of the actuator includes the operation to move the head to the
reference cylinder, the seek operation to move the head to the target cylinder to
read or write data, and the track-following operation to position the head onto the
target track.
(1) Operation to move the head to the reference cylinder
The MPU moves the head to the reference cylinder when the power is turned.
The reference cylinder is in the data area.
When power is applied the heads are moved from the inner circumference shunt
zone to the normal servo data zone in the following sequence:
a)
Micro current is fed to the VCM to press the head against the outer
circumference.
b)
The head is loaded on the disk.
c)
When the servo mark is detected the head is moved slowly toward the inner
circumference at a constant speed.
Summary of Contents for MHN2100AT - Mobile 10 GB Hard Drive
Page 1: ...C141 E120 02EN MHN2300AT MHN2200AT MHN2150AT MHN2100AT DISK DRIVES PRODUCT MANUAL ...
Page 4: ...This page is intentionally left blank ...
Page 8: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 32: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 52: ...Installation Conditions 3 14 C141 E120 02EN Figure 3 16 Example 2 of Cable Select drive drive ...
Page 58: ...Theory of Device Operation 4 6 C141 E120 02EN Figure 4 3 Circuit Configuration ...
Page 76: ...This page is intentionally left blank ...
Page 174: ...Interface 5 98 C141 E120 02EN g d f f d e Figure 5 7 Normal DMA data transfer ...
Page 224: ...This page is intentionally left blank ...
Page 228: ...This page is intentionally left blank ...
Page 230: ...This page is intentionally left blank ...
Page 232: ...This page is intentionally left blank ...
Page 234: ...This page is intentionally left blank ...
Page 235: ......
Page 236: ......