![Fujitsu MBA3300 NP SERIES Technical Manual Download Page 136](http://html.mh-extra.com/html/fujitsu/mba3300-np-series/mba3300-np-series_technical-manual_118322136.webp)
56
C141-C015
Table 1.26
TYPE
Codes Type
Description
01h Last
Command
Sent by a SCSI initiator device to indicate a SPI command information unit
shall follow this SPI L_Q information unit. Indicates the SCSI initiator device
shall not send any more SPI command information units during the current
connection. The value of the DATA LENGTH field shall be greater than or
equal to 14h and less than or equal to 90h. The IUCRC INTERVAL field
shall be set to zero and ignored by the SCSI target device. The BIDI
DIRECTION field shall be set to zero and ignored by the receiving SCSI
target device.
02h Multiple
Command
Sent by a SCSI initiator device to indicate a SPI command information unit
shall follow this SPI L_Q information unit. Indicates the SCSI initiator device
has another SPI L_Q information unit and SPI command information unit
during the current connection. The value of the DATA LENGTH field shall
be greater than or equal to 14h and less than or equal to 90h. The IUCRC
INTERVAL field shall be set to zero and ignored by the SCSI target device.
The IUCRC INTERVAL field shall be set to zero and ignored by the SCSI
target device. The BIDI DIRECTION field shall be set to zero and ignored by
the receiving SCSI target device.
04h Data
Sent by a SCSI target device to indicate a SPI data information unit shall
follow this SPI L_Q information unit. The DATA LENGTH field shall not be
set to zero. For a bidirectional command, the direction of the SPI data infor-
mation unit shall be indicated in the BIDI DIRECTION field of the SPI L_Q
in-formation unit as defined in table 1.27.
05h Data
Stream
Sent by a SCSI target device to indicate an unspecified number of SPI data
stream information unit shall follow this SPI L_Q information unit. The
DATA LENGTH field shall not be set to zero. For a bidirectional command,
the direction of the SPI data stream information units shall be indicated in the
BIDI DIRECTION field of the SPI L_Q information unit as defined in table
1.27.
08h Status
Sent by a SCSI target device to indicate a SPI status information unit may
follow this SPI L_Q information unit. A length of zero in the DATA
LENGTH field shall indicate no SPI status information unit shall follow the
SPI L_Q information unit (see 1.9.3.5). The IUCRC INTERVAL field shall
be set to zero and ignored by the SCSI initiator device. The IUCRC
INTERVAL field shall be set to zero and ignored by the SCSI target device.
The BIDI DIRECTION field shall be set to zero and ignored by the receiving
SCSI initiator device.
F0h - FFh
Vendor specific
All others
Reserved
The TAG field is a 16-bit integer assigned by the application client and sent to the INIT in the
send SCSI command request.
Summary of Contents for MBA3300 NP SERIES
Page 6: ...This page is intentionally left blank ...
Page 18: ...This page is intentionally left blank ...
Page 69: ...C141 C015 63 Figure 1 26 ARBITRATION phase ...
Page 81: ......
Page 117: ...1 37 C141 C007 Figure 1 43 Bus phase sequence 1 of 2 ...
Page 118: ...38 C141 C015 Figure 1 43 Bus phase sequence 2 of 2 ...
Page 128: ...48 C141 C015 Figure 1 47 SPI information unit sequence during initial connection ...
Page 129: ...1 49 C141 C007 Figure 1 48 SPI information unit sequence during data type transfers ...
Page 130: ...50 C141 C015 Figure 1 49 SPI information unit sequence during data stream type transfers ...
Page 131: ...1 51 C141 C007 Figure 1 50 SPI information unit sequence during status transfers ...
Page 155: ...1 75 C141 C007 Figure 1 56 Connection to the LVD receivers ...
Page 161: ...Figure 2 1 Message format 154 C141 C015 ...
Page 166: ...Figure 2 2 SCSI pointer configuration C141 C015 159 ...
Page 201: ...This page is intentionally left blank ...
Page 205: ...This page is intentionally left blank ...
Page 207: ...This page is intentionally left blank ...
Page 208: ......
Page 209: ......