5.2 Setting
5.2 Setting
5.2.1
Loop ID setting
When setting the fibre channel loop ID, use SEL0 to SEL6 of interface connector CN1. In bit
weighting, SEL6 corresponds to the MSB, SEL0 to the LSB, and 126 types of X'00' to X'7D' can be
specified as loop IDs.
5.2.2
Mode settings
(1)
Motor start mode
The method for start control of the HDD spindle motor can be set in accordance with Table 5.1.
Table 5.1
Motor start mode
Setting
Signal name
Start_2/Mated Start_1/Mated
Start
mode
Connector pin
CN1-10 pin
CN1-09 pin
Open
Open
The HDD is not connected to the system. The HDD does not start
the spindle motor.
Open
GND
The HDD is connected to the system. After recognizing the
connection, the HDD starts the spindle motor upon receipt of a
START/STOP UNIT command.
GND
Open
The HDD is connected to the system. After recognizing the
connection, the HDD starts the spindle motor after a prescribed delay
time has elapsed.
GND
GND
The HDD is connected to the system. The HDD starts the spindle
motor immediately after recognizing the connection.
Set the loop ID so that there are no duplicates between devices on the
same loop.
C141-E264
55
Summary of Contents for MBA3073FD
Page 1: ...C141 E264 01EN MBA3300FD MBA3147FD MBA3073FD HARD DISK DRIVES PRODUCT MANUAL ...
Page 4: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 32: ...This page is intentionally left blank ...
Page 74: ...This page is intentionally left blank ...
Page 90: ...This page is intentionally left blank ...
Page 96: ...This page is intentionally left blank ...
Page 102: ...This page is intentionally left blank ...
Page 104: ...This page is intentionally left blank ...
Page 105: ......
Page 106: ......