Installation Requirements
(5) Environmental
temperature
Temperature condition at installed in a cabinet is indicated with ambient temperature measured
30 mm from the HDD. At designing the system cabinet, consider following points.
•
Make a suitable air flow so that the DE surface temperature never exceed 60°C.
•
Cool the PCBA side especially with air circulation inside the cabinet. Confirm the cooling effect
by measuring the surface temperature of specific ICs and the DE. These measurement results
must satisfy the temperature condition listed in Table 4.1.
•
Keep the DE surface temperature at 50
°
C or below to meet the condition for assuring an MTBF
of 1,400,000 hours. An air flow of 1.0 m/s or more is required at ambient temperature 30
°
C.
Table 4.1
Surface temperature check point and maximum temperature
No.
Measurement point
Maximum temperature
1 DE
Surface
60°C
2
Read channel LSI
82°C
3 VCM/SPM
Driver
100°C
4 HDC
100°C
5 MPU
94°C
1
4
2
3
5
Figure 4.5 Surface temperature measurement points
46
C141-E264
Summary of Contents for MBA3073FD
Page 1: ...C141 E264 01EN MBA3300FD MBA3147FD MBA3073FD HARD DISK DRIVES PRODUCT MANUAL ...
Page 4: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 32: ...This page is intentionally left blank ...
Page 74: ...This page is intentionally left blank ...
Page 90: ...This page is intentionally left blank ...
Page 96: ...This page is intentionally left blank ...
Page 102: ...This page is intentionally left blank ...
Page 104: ...This page is intentionally left blank ...
Page 105: ......
Page 106: ......