8.4 Power-On Sequence
C141-E133-02EN
8-5
8.4
Power-On Sequence
Figure 8.2 shows the operation sequence of the IDD at power-on. The processes shown in this figure
are explained below:
1) After the power is turned on, the IDD executes self-diagnosis 1 (MPU bus test, internal register
write/read test, and work RAM write/read test).
2) When self-diagnosis 1 terminates successfully, the IDD activates the spindle motor when the
motor start mode is set.
3) The IDD executes self-diagnosis 2 (data buffer write/read test).
4) The IDD receives the START UNIT command, then the IDD activates the spindle motor when
the motor start mode is set. When the motor start mode is not set, the IDD terminates this
sequence and enters the command waiting state.
5) The IDD checks that the spindle motor rotation reaches a steady rotational speed.
6) The IDD executes self-configuration. This includes execution of the factory calibration which is
described on the next page and the processing of reading the format information and defect
position information written in the system zone.
7) The disk drive is in ready state and commands from the host system can be executed.
Motor start mode
setting
ON
OFF
(7)
(6)
(5)
(4)
ON
OFF
(3)
(2)
(1)
Power-on
Self-diagnosis 1
• MPU bus test
• Internal register
write/read test
• Work RAM write/read
test
Start
Activate spindle motor
Self-diagnosis 2
• Data buffer write/read
test
Motor start mode
switch setting
Check spindle motor
steady state rotation
Execute self-calibration
Drive ready state
(command waiting state)
End
Figure 8.2
IDD operation sequence at power-on
Summary of Contents for MAN3367FC - Enterprise 36.7 GB Hard Drive
Page 1: ...C141 E133 02EN MAN3735FC SERIES MAN3367FC SERIES DISK DRIVES PRODUCT MAINTENANCE MANUAL ...
Page 4: ......
Page 6: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 21: ...Contents C141 E133 02EN xv Glossary GL 1 Abbreviations AB 1 Index IN 1 ...
Page 24: ...This page is intentionally left blank ...
Page 40: ...This page is intentionally left blank ...
Page 56: ...This page is intentionally left blank ...
Page 66: ...Installation Requirements 4 10 C141 E133 02EN Figure 4 10 SCA2 type connector ...
Page 110: ...Principle of Operation 8 8 C141 E133 02EN Figure 8 3 Block diagram of read write circuit ...
Page 116: ...This page is intentionally left blank ...
Page 132: ...This page is intentionally left blank ...
Page 136: ...This page is intentionally left blank ...
Page 144: ...This page is intentionally left blank ...
Page 146: ...This page is intentionally left blank ...
Page 147: ......
Page 148: ......