3.1 Data Space
C141-E133-02EN
3-9
(5)
BCRC
It is a 4-byte error detection code. Errors in the ID field. Single burst errors with lengths of up to 32
bits for each logical block can be detected.
(6)
ECC
This is the 60-byte code that allows detection and correction of errors in the data field, which is
capable of correcting the single burst error up to 240 bits max. on the fly.
(7)
PAD
A specified length of x‘00’ pattern shown in Figure 3.6 is written in this field. This field includes the
variation by rotation and circuit delay till reading/writing.
3.1.5
Format capacity
The size of the usable area for storing user data on the IDD (format capacity) varies according to the
logical data block or the size of the spare sector area. Table 3.2 lists examples of the format capacity
when the typical logical data block length and the default spare area are used. The following is the
general formula to calculate the format capacity.
[Number of sectors of each zone] = [number of sectors per track
×
number of tracks (heads) –
number of alternate spare sectors per cylinder]
×
[number of cylinders in the zone]
[Formatted capacity] = [total of sectors of all zones] – [number of sectors per track in last zone
×
number of tracks (heads)
×
number of alternate cylinders]
÷
[number of physical sectors in logical
block]
×
[logical data block length]
The following formula must be used when the number of logical data blocks are specified with the
parameter in the MODE SELECT or MODE SELECT EXTENDED command.
[Format capacity] = [logical data block length]
×
[number of logical data blocks]
The logical data block length, the maximum logical block address, and the number of the logical data
blocks can be read out by a READ CAPACITY, MODE SENSE, or MODE SENSE EXTENDED
command after initializing the disk medium.
Summary of Contents for MAN3367FC - Enterprise 36.7 GB Hard Drive
Page 1: ...C141 E133 02EN MAN3735FC SERIES MAN3367FC SERIES DISK DRIVES PRODUCT MAINTENANCE MANUAL ...
Page 4: ......
Page 6: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 21: ...Contents C141 E133 02EN xv Glossary GL 1 Abbreviations AB 1 Index IN 1 ...
Page 24: ...This page is intentionally left blank ...
Page 40: ...This page is intentionally left blank ...
Page 56: ...This page is intentionally left blank ...
Page 66: ...Installation Requirements 4 10 C141 E133 02EN Figure 4 10 SCA2 type connector ...
Page 110: ...Principle of Operation 8 8 C141 E133 02EN Figure 8 3 Block diagram of read write circuit ...
Page 116: ...This page is intentionally left blank ...
Page 132: ...This page is intentionally left blank ...
Page 136: ...This page is intentionally left blank ...
Page 144: ...This page is intentionally left blank ...
Page 146: ...This page is intentionally left blank ...
Page 147: ......
Page 148: ......