2-6
Connecting the interface cables
Connect the SCSI interface cables and secure them.
NOTICE
Factory default for SCSI terminator is ON. If the scanner is in the middle of the daisy chain or two devices,
turn the scanner termination off via operartor’s panel.
NOTICE
Factory default for SCSI ID is 5. If the ID of the scanner is the same as the other device, change the ID
via operator’s panel or change the ID of the other device.
Back of the image scanner
Interface cables
To
the host
system