background image

1

XGUARD-10/-5

EN

XGUARD-10: max. detection range of 9.9 m x 9.9 m
XGUARD-5: max. detection range of 5.0 m x 5.0 m

LASER SCANNERS foR iNDUStRiAL DooRS

User’s Guide

 for product version 0600 and more

Summary of Contents for XGUARD-10

Page 1: ...1 XGUARD 10 5 EN XGUARD 10 max detection range of 9 9 m x 9 9 m XGUARD 5 max detection range of 5 0 m x 5 0 m LASER SCANNERS for industrial doors User s Guidefor product version 0600 and more...

Page 2: ...s responsible for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety and if...

Page 3: ...laser sweep reception 3 LED signal 4 4 screw for position lock 2 5 connector 6 protection cover 7 visible laser beam 3 8 notch for tilt angle adjustment 2 9 adjustable bracket 10 cable conduit 4 1 De...

Page 4: ...ble 10 cm though the cable opening If drilling an opening is not possible use the cable conduits on the back side of the bracket Position the bracket and fasten the 4 screws firmly in order to avoid v...

Page 5: ...the postion of curtain C1 and limit the angle of the detection field The visible laser beams stay activated for 15 minutes or can be turned off the same way they were activated Door control without t...

Page 6: ...m no field no field The detection field should be free of snow buildups heavy rain snowfall fog or other moving objects Stay outside of the detection field to avoid disturbances Select the correspondi...

Page 7: ...stance between the first and the last curtain is approximately 10 cm for every meter mounting height Example at 5 m the distance is 50 cm indoor outdoor low outdoor med outdoor high OUTPUT ACTIVATION...

Page 8: ...he sensor position is changed or new objects are added to or changed in the detection zone ATTENTION This PB teach in is different from the safety field teach in When the red LED flashes very slowly a...

Page 9: ...VALUES SAVING AN ACCESS CODE DELETING AN ACCESS CODE The access code is recommended for sensors installed close to each other After unlocking the red LED flashes and the sensor can be adjusted by rem...

Page 10: ...and BLUE cable have to be connected to the test input or the power supply Check the size of the fields Launch a teach in Step out of the field and or remove the any object s from the field Activate th...

Page 11: ...cm 10 m XGUARD 5 2 1 cm 3 m 3 5 cm 5 m 700 mm x 300 mm x 200 mm testbody A according to EN 12445 wavelength 905 nm max output pulse power 75 W CLASS 1 wavelength 650 nm max output CW power 3 mW CLASS...

Page 12: ...FAAC XGUARD 10 5 is in conformity with the basic requirements and the other relevant provi sions of the directives 2006 95 EC 2002 95 EC 2004 108 EC and 2006 42 EC Notified Body for EC inspection 004...