background image

7

5

10

15

20

cm

R1

R2

R1

R2

cm

10

15

20

25

5

CAT 2

R1 R2

A - NO

P - NC

A - NO

P - NC

P - NC

A - NO

P - NC

A - NO

LZR

®

-I100

LZR

®

-I110

CAT 2

CAT 2

CAT 2

CAT 2

CAT 2

CAT 2

CAT 2

ms

100

200

300

400

500

600

700

800

900

X

X

X

X

REMOTE CONTROL ADJuSTMENTS (OPTIONAL)

FACTORy VALUES

ImmunIty fILteR

mIn. OBJeCt SIZe

OutPut COnfIGuRAtIOn

DeteCtIOn fIeLD

ReDIReCtIOn

(approximate values)

unCOVeReD ZOne

Increase in case of snow, dead leaves, etc.

optional

safety

safety

optional

or safety

DeteCtIOn CuRtAInS

indoor outdoor

low

outdoor

med

outdoor

high

off

The distances between the curtains depend on the mounting height and side. When mounted on the left, the distance between the first 
and the last curtain is approximately 10 cm for every meter (mounting height). 

Example

: at 5 m the distance is 50 cm.

indoor outdoor

low

outdoor

med

outdoor

high

OutPut ACtIVAtIOn DeLAy 

(approximate values)

off

EX:

C1 + C2 active on optional field only
C3 + C4 active on safety field only

C1 active on both fields
C2+C3 active on safety field only
C4 deactivated

CuRtAIn

    C1    C2    C3    C4

C1
C2
C3
C4

The outputs are triggered after a constant 
detection time of x ms (ex. value 3= 300 ms).

deactivate curtain on both fields

activate curtain only on optional field

activate curtain only on safety field

activate curtain on both fields

Increased sensitive (detection of black 
objects, ...)

Increased immunity to rain, snow, fog...

All curtains active on both fields

Rx = RELAy OUTPUT

A = active

P = passive

NO = normally open

NC = normally closed

Summary of Contents for XGUARD-10

Page 1: ...1 XGUARD 10 5 EN XGUARD 10 max detection range of 9 9 m x 9 9 m XGUARD 5 max detection range of 5 0 m x 5 0 m LASER SCANNERS for industrial doors User s Guidefor product version 0600 and more...

Page 2: ...s responsible for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety and if...

Page 3: ...laser sweep reception 3 LED signal 4 4 screw for position lock 2 5 connector 6 protection cover 7 visible laser beam 3 8 notch for tilt angle adjustment 2 9 adjustable bracket 10 cable conduit 4 1 De...

Page 4: ...ble 10 cm though the cable opening If drilling an opening is not possible use the cable conduits on the back side of the bracket Position the bracket and fasten the 4 screws firmly in order to avoid v...

Page 5: ...the postion of curtain C1 and limit the angle of the detection field The visible laser beams stay activated for 15 minutes or can be turned off the same way they were activated Door control without t...

Page 6: ...m no field no field The detection field should be free of snow buildups heavy rain snowfall fog or other moving objects Stay outside of the detection field to avoid disturbances Select the correspondi...

Page 7: ...stance between the first and the last curtain is approximately 10 cm for every meter mounting height Example at 5 m the distance is 50 cm indoor outdoor low outdoor med outdoor high OUTPUT ACTIVATION...

Page 8: ...he sensor position is changed or new objects are added to or changed in the detection zone ATTENTION This PB teach in is different from the safety field teach in When the red LED flashes very slowly a...

Page 9: ...VALUES SAVING AN ACCESS CODE DELETING AN ACCESS CODE The access code is recommended for sensors installed close to each other After unlocking the red LED flashes and the sensor can be adjusted by rem...

Page 10: ...and BLUE cable have to be connected to the test input or the power supply Check the size of the fields Launch a teach in Step out of the field and or remove the any object s from the field Activate th...

Page 11: ...cm 10 m XGUARD 5 2 1 cm 3 m 3 5 cm 5 m 700 mm x 300 mm x 200 mm testbody A according to EN 12445 wavelength 905 nm max output pulse power 75 W CLASS 1 wavelength 650 nm max output CW power 3 mW CLASS...

Page 12: ...FAAC XGUARD 10 5 is in conformity with the basic requirements and the other relevant provi sions of the directives 2006 95 EC 2002 95 EC 2004 108 EC and 2006 42 EC Notified Body for EC inspection 004...

Reviews: