M3099GX/GH OEM Manual
3-49
INTERFACE
REQUEST SENSE Command (See ANSI SCSI-2 8.2.14)
The REQUEST SENSE command (Table 3.27) requests that the
target transfer sense data to the initiator.
Table 3.27 REQUEST SENSE Command
Bit
Byte
0
1
2
3
4
5
7
6
5
3
2
1
0
Operation Code (03h)
Reserved
Reserved
Allocation Length
Control
Logical Unit Number
4
Reserved
The sense data:
1) shall be available if a contingent allegiance condition exists for the
I_T_x nexus;
2) shall be available if other information is available in any field;
3) may be available if an unexpected disconnect occurred.
If the target has no other sense data available to return, it shall return
a sense key of NO SENSE and an additional sense code of NO
ADDITIONAL SENSE INFORMATION.
The sense data shall be preserved by the target for the initiator until
retrieved by a REQUEST SENSE command or until the receipt of
any other I/O process for the same I_T_x nexus. Sense data shall be
cleared upon receipt of any subsequent I/O process (including
REQUEST SENSE) to the same I_T_x nexus.
The sense data format for error code 70h(current errors) is
supported.
#03.pm5
98.2.22, 1:32 PM
49
Summary of Contents for C150-E049-02EN
Page 1: ...M3099GX GH IMAGE SCANNER OEM MANUAL C150 E049 02EN 00 1 Cover pm5 98 2 22 1 13 PM 1 ...
Page 2: ...M3099GX GH IMAGE SCANNER OEM MANUAL 00 1 Cover pm5 98 2 22 1 13 PM 2 ...
Page 3: ... 00 1 Cover pm5 98 2 22 1 13 PM 3 ...
Page 157: ...3 124 M3099GX GH OEM Manual 03 pm5 98 2 22 1 34 PM 124 ...
Page 185: ...5 6 M3099GX GH OEM Manual 05 Chapter 5 98 2 22 1 51 PM 6 ...
Page 205: ...8 10 M3099GX GH OEM Manual 08 Chapter 8 98 2 22 1 53 PM 10 ...
Page 225: ...M3099GX GH OEM Manual B 14 A 3 Appendix B 98 2 22 2 42 PM 14 ...