DIP switch setting
•
SW100: Remote controller address setting
NOTE:
Because this setting is normally done automatically when 2-core wired remote con-
troller is installed, setting is unnecessary.
Multiple indoor units can be operated by using one wired remote controller.
Set the unit number of each indoor unit.
Remote
controller
address
DIP switch number
Factory setting
1
2
3
4
00
OFF
OFF
OFF
OFF
♦
01
ON
OFF
OFF
OFF
02
OFF
ON
OFF
OFF
03
ON
ON
OFF
OFF
04
OFF
OFF
ON
OFF
05
ON
OFF
ON
OFF
06
OFF
ON
ON
OFF
07
ON
ON
ON
OFF
08
OFF
OFF
OFF
ON
09
ON
OFF
OFF
ON
10
OFF
ON
OFF
ON
11
ON
ON
OFF
ON
12
OFF
OFF
ON
ON
13
ON
OFF
ON
ON
14
OFF
ON
ON
ON
15
ON
ON
ON
ON
NOTES:
• When connecting Polar 3-core wired remote controller, set the remote controller address
in the order of 0, 1, 2, ....., and 15.
• When different type of indoor units (such as wall-mounted type and cassette type, cas-
sette type and duct type, or other combinations) are connected using group control sys-
tem, some functions may no longer be available.
00
01
02
Remote controller address
Indoor unit
Remote controller
•
SW101: Setting change prohibited
- 49 -
9-1. Function settings on indoor unit
9. Function settings
C
A
SSET
TE
TYPE
A
U
XG
24
-5
4K
R
LB
C
A
SSET
TE
TYPE
A
U
XG
24
-5
4K
R
LB