background image

En-2

OPERATING MANUAL

 

WARNING

• Do not install the unit in area 

¿

 lled with mineral oil such as a 

factory or area containing a large amount of splashed oil or 
steam such as a kitchen.

• Do not start or stop the operation of this product by inserting 

or pulling out the power plug, or by turning on or off the 
circuit breaker.

• Do not use in

À

 ammable gases near the unit.

• Do not expose yourself directly to the cooling air

À

 ow for 

many hours.

• Do not insert your 

¿

 ngers or any other objects into outlet 

port, open panel, or intake grille.

• Do not operate with wet hands.
• Do not use means to accelerate the defrosting process or to 

clean the appliance, other than those recommended by the 
manufacturer.

• Do not pierce or burn.

 

CAUTION

• Provide occasional ventilation during use.

• Always operate the unit with air 

¿

 lters installed.

• Ensure that any electronic equipment is at least 1 meter 

away from either the indoor unit or outdoor unit.

• Unplug the power supply cable when not using the indoor 

unit for an extended period.

• After long period of use, check whether the installation stand 

does not deteriorate to prevent the unit from falling down.

• The air

À

 ow direction and the room temperature should be 

carefully considered when you use this product in a room 
with infants, children, elderly or sick persons.

• Do not place vase or water container on the unit.

• Do not place any other electrical products or household 

belongings under indoor unit or outdoor unit.

  Dripping condensation from the unit might get them wet, and 

may cause damage or malfunction of your property.

• Do not expose the unit directly to water.

• Do not use this product for preservation of food, plants, 

animals, precision equipment, art work, or other objects. This 
may cause quality deterioration of those items.

• Do not expose animals or plants to the direct air

À

 ow.

• Do not drink the drainage from the air conditioner.

• Do not pull the power supply cable to disconnect the plug.

• Do not touch the aluminum 

¿

 ns of heat exchanger built-in 

the indoor or outdoor unit to avoid personal injury when you 
install or maintain the unit.

• Do not direct the air

À

 ow at 

¿

 replaces or heating apparatus.

• Do not block or cover the intake grille and the outlet port.

• Do not apply any heavy pressure to radiator 

¿

 ns.

•  Do not climb on, place objects on, or hang objects from the unit.

Safety Precautions (continued)

 Indoor unit accessories

Remote 
controller

Batteries

Air cleaning 

¿

 lters

Filter holders

Remote controller 
holder

Tapping screws
(M3 × 12 mm)

Remote controller holder installation

3

2

1

Screws

Insert

Slide up

 

WARNING

Take care to prevent infants and young children from acciden-
tally swallowing the batteries.

 

CAUTION

• Do not attempt to recharge dry batteries.

• Do not use dry batteries that has been recharged.

 

Battery (R03/LR03/AAA × 2) loading and remote controller preparation

1

4

2

3

6

7

8

5

9

5

    Press CLOCK ADJUST button to start clock setting.

6

    Set the day of the week by pressing SELECT button (Monday to 

Sunday). *By pressing the TEMP. (

š›

) buttons, the time indicator 

can be changed from a 24-hour to a 12-hour clock.

7

    Press NEXT button to continue.

8

    Set the time by pressing SELECT button.

Pressing 

U

 or 

V

 changes the value by the minute.

Pressing down on 

U

 or 

V

 changes the value by 10 minutes.

9

    To complete, press the SEND button close to the indoor unit. 

Settings may not be properly sent if pressed from a distance.

Notes:

•  Use speci

¿

 ed type of batteries only.

•  Do not mix different types or new and used batteries together.
• Batteries can be used about 1 year in ordinary use.
•  If the remote control range noticeably shortens, replace the batter-

ies, and press RESET button as shown in page 5.

9320455088_OM_EN.indd   2

3/23/2017   1:55:02 PM

Summary of Contents for ASTG18CMCB

Page 1: ...y authorized service personnel In the event of refrigerant leakage be sure to keep away from re or any Àammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning strike turn off the air conditioner via the remote controller and refrain from touching the product or the power source to prevent any electrical hazards The appliance shall be stor...

Page 2: ...is may cause quality deterioration of those items Do not expose animals or plants to the direct airÀow Do not drink the drainage from the air conditioner Do not pull the power supply cable to disconnect the plug Do not touch the aluminum ns of heat exchanger built in the indoor or outdoor unit to avoid personal injury when you install or maintain the unit Do not direct the airÀow at replaces or he...

Page 3: ...t to position 5 8 for more than 30 minutes in COOL or DRY mode the louver will automatically return to position 4 Keeping the position 5 8 during COOL or DRY mode may cause condensation to form and the drops may damage your property 7 Power diffuser In conjunction with movement of the vertical airÀow direction louver the angle of the power diffuser moves as follows Vertical airÀow direction louver...

Page 4: ...ption In actual operation the display is linked with the button operation and only shows the necessary indicators for each setting 5 POWERFUL button Activates the POWERFUL operation The unit will operate at maximum power and strong airÀow to quickly cool down the room When activated the indoor unit will emit 3 short beeps To turn off press the POWERFUL button again The indoor unit will then emit 2...

Page 5: ...o fall asleep comfortably with gradual temperature control See page 6 14 ON OFF timer button Activates the ON OFF timer 15 NEXT button Used for adjusting the timer setting 16 BACK button Used for adjusting the timer setting 17 RESET button When you press the RESET button press it gently by using the tip of a ballpoint pen or other small object in correct direction as shown in this gure RESET 18 TE...

Page 6: ...e set time has elapsed Set temperature Set time 1 hour 2 C 1 C In COOL or DRY mode continued Remote controller custom code setting When two or more air conditioners are installed in a room and the remote controller is operating an air conditioner other than the one you wish to set change the custom code of the remote controller to operate only the air conditioner you wish to set 4 selections possi...

Page 7: ... timers If you want to run the product on WEEKLY timer after using the ON OFF timer Program timer or SLEEP timer while the WEEKLY timer is running you need to activate the WEEKLY timer again To set the WEEKLY timer rst follow steps on page 6 for the ON OFF timer 4 Select the program number and the day using the SELECT button Program 1Week Program Monday Program Tuesday Program Sunday Program 1Week...

Page 8: ...s or electric appli ances such as oscillating electric fans operating Notice This product is designed to be compatible with Air Conditioning Demand Response program To utilize the function you need a separate arrangement with your electricity supplier Please check availability in the place of use When your electricity supplier activates one of the following 3 Demand Response DR modes the air condi...

Page 9: ... of a wireless radio transmitter may cause the malfunction of the air conditioner If you encounter such a malfunction turn off the circuit breaker once Then turn it on again and resume operation by using the remote controller Temperature and Humidity Range Permissible ranges of temperature and humidity are as follows COOL DRY Indoor temperature About 18 C to 32 C Indoor humidity Below approximatel...

Page 10: ...top of the panel a To latch each shaft properly insert the shaft until it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air lters Mind that you have a periodical cleaning of the air lters to prevent reducing the operation ef ciency of the product Using of clogged air lter with dust will lower the product performance and may c...

Page 11: ...is left with the package opened Replace the lter once every 3 months under normal use By setting the fan speed high the air cleaning effect increases Ion deodorization lter UTR FA16 2 Light blue 1 sheet The lter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra ne particle ceramic To maintain the deodorizing effect clean the...

Page 12: ...ode the indoor unit fan may stop from time to time when the outdoor unit is stopped 4 When monitoring operation is performed in AUTO mode the fan rotates at very low speed Before you call for or request servicing troubleshoot a problem by performing following checks Symptom Diagnostic See page Does not operate at all Has the circuit breaker been turned off Has there been a power outage Has a fuse ...

Reviews: