background image

En-7

AIR CONDITIONER Wall Mounted Type

OPERATING MANUAL

Timer Operation (continued)

 WEEKLY timer

ON and OFF timer can be combined, and up to 4 reservations (program 

 ) per day and 28 reservations per week.

Before setting the program, please set the week and time of the air 
conditioner 

¿

 rst.

If the week and time are not set, the weekly timer will not operate 
correctly at the set time.
Please refer to "remote controller preparation"  (page 2).

Example of WEEKLY timer 1

No timer settings

Program 

9:00  

OFF

Program 

11:00  

OFF

Program 

17:00  

OFF

Program 

23:00  

OFF

Monday to 

Friday

Saturday

Sunday

Program 

7:00 

ON 

26°C

Program 

9:00 

OFF

Wake up

Leave for work

Program 

17:00 

ON 

28°C

Program 

23:00 

OFF

Come back home

Go to sleep

ON

ON

ON

ON

Example of WEEKLY timer 2

You can specify a given temperature in the ON setting in WEEKLY 
timer.

Program 

7:00  

ON  

28°C

Program 

9:00  

ON  

26°C

Program 

17:00  

ON  

27°C

Program 

23:00  

ON  

28°C

* You can set the temperature for AUTO, COOL, and DRY modes within 
the range of 18-30°C.

Notes:

Ɣ

 Operations modes other than the temperature setting will be the 

same at the last time operation was stopped, so Cooling 

ĺ

 Dry 

ĺ

 

Cooling 

ĺ

 Dry type of operations cannot be automatically set.

Ɣ

 If you set the ON timer and OFF timer on the same time, the air 

conditioner will run the ON timer. If two ON timer are set at the 
same time, the air conditioner will run in the order of the program 
number.

Ɣ

 If there is a power interruption, such as due to a power outage 

during the WEEKLY timer setting or a circuit breaker cutting out, 
the internal timer of the air-conditioning will be incorrect. (See page 
9 "Auto-restart function".) In such a case, the main timer lamp will 
notify you of this by 

À

 ashing, so carry out matching of the time and 

date. (See page 2 "remote controller preparation".)

Ɣ

 You cannot use the WEEKLY timer together with the other timers.

If you want to run the product on WEEKLY timer after using the 
ON/OFF timer, Program timer, or SLEEP timer while the WEEKLY 
timer is running, you need to activate the WEEKLY timer again.

To set the WEEKLY timer, 

¿

 rst follow steps 

~

 on page 6 for 

the ON/OFF timer.

4

  Select the program number and the day using the SELECT 

button.

Program

 1Week

Program

 Monday Program

 Tuesday

Program

 Sunday

Program

 1Week

Program

 Monday

Program

 Saturday Program

 Sunday

 

Press the NEXT button, when the program number and day you 
want to set are 

À

 ashing.

5

  Using the SELECT button select the operation mode (ON timer, 

OFF timer, or without a timer).

To operate without a timer

1.   Press the NEXT button to go back to step 4

 

and con

¿

 gure the 

next setting.

2.  Press the SEND button to 

¿

 nish

 

Press the NEXT button.

6

  Press the SELECT button  to set the desired ON time or OFF 

time.

If you selected OFF in step 5

1.   Press the NEXT button to go back to step 4 and con

¿

 gure the 

next setting.

2.  Press the SEND button.

 

Press the NEXT button.

7

  Press the SELECT button to set the temperature.

If you want to move on to the next setting, press the NEXT button, 
return to step 4 and con

¿

 gure the next setting.

8

  To complete the setting, press the SEND button.

If you want to cancel the setting midway, please press the 
TIMER SETTING button instead of pressing the SEND button.

Notes:

Ɣ

  When canceling the WEEKLY timer, select without a timer 

Operation in Step 5 in the WEEKLY timer setting.

Ɣ

  If you want to go back to the previous step when con

¿

 guring 

settings, press the BACK button to return to the previous step.

Ɣ

  Press the SEND button, when you are close to the main unit. If you 

do so when far from the main unit, the signal may not get properly 
sent, and the settings may not get properly con

¿

 gured.

Ɣ

  To check the schedule, repeat steps 1 to 3 to enter the WEEKLY 

timer mode, then use the SELECT button to browse through the 
WEEKLY timer settings in the order shown in step 4.

Ɣ

  To cancel the WEEKLY timer, press the WEEKLY button while the 

WEEKLY indicator is on. (Erases the indicator)

9320455088_OM_EN.indd   7

3/23/2017   1:55:04 PM

Summary of Contents for ASTG18CMCB

Page 1: ...y authorized service personnel In the event of refrigerant leakage be sure to keep away from re or any Àammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning strike turn off the air conditioner via the remote controller and refrain from touching the product or the power source to prevent any electrical hazards The appliance shall be stor...

Page 2: ...is may cause quality deterioration of those items Do not expose animals or plants to the direct airÀow Do not drink the drainage from the air conditioner Do not pull the power supply cable to disconnect the plug Do not touch the aluminum ns of heat exchanger built in the indoor or outdoor unit to avoid personal injury when you install or maintain the unit Do not direct the airÀow at replaces or he...

Page 3: ...t to position 5 8 for more than 30 minutes in COOL or DRY mode the louver will automatically return to position 4 Keeping the position 5 8 during COOL or DRY mode may cause condensation to form and the drops may damage your property 7 Power diffuser In conjunction with movement of the vertical airÀow direction louver the angle of the power diffuser moves as follows Vertical airÀow direction louver...

Page 4: ...ption In actual operation the display is linked with the button operation and only shows the necessary indicators for each setting 5 POWERFUL button Activates the POWERFUL operation The unit will operate at maximum power and strong airÀow to quickly cool down the room When activated the indoor unit will emit 3 short beeps To turn off press the POWERFUL button again The indoor unit will then emit 2...

Page 5: ...o fall asleep comfortably with gradual temperature control See page 6 14 ON OFF timer button Activates the ON OFF timer 15 NEXT button Used for adjusting the timer setting 16 BACK button Used for adjusting the timer setting 17 RESET button When you press the RESET button press it gently by using the tip of a ballpoint pen or other small object in correct direction as shown in this gure RESET 18 TE...

Page 6: ...e set time has elapsed Set temperature Set time 1 hour 2 C 1 C In COOL or DRY mode continued Remote controller custom code setting When two or more air conditioners are installed in a room and the remote controller is operating an air conditioner other than the one you wish to set change the custom code of the remote controller to operate only the air conditioner you wish to set 4 selections possi...

Page 7: ... timers If you want to run the product on WEEKLY timer after using the ON OFF timer Program timer or SLEEP timer while the WEEKLY timer is running you need to activate the WEEKLY timer again To set the WEEKLY timer rst follow steps on page 6 for the ON OFF timer 4 Select the program number and the day using the SELECT button Program 1Week Program Monday Program Tuesday Program Sunday Program 1Week...

Page 8: ...s or electric appli ances such as oscillating electric fans operating Notice This product is designed to be compatible with Air Conditioning Demand Response program To utilize the function you need a separate arrangement with your electricity supplier Please check availability in the place of use When your electricity supplier activates one of the following 3 Demand Response DR modes the air condi...

Page 9: ... of a wireless radio transmitter may cause the malfunction of the air conditioner If you encounter such a malfunction turn off the circuit breaker once Then turn it on again and resume operation by using the remote controller Temperature and Humidity Range Permissible ranges of temperature and humidity are as follows COOL DRY Indoor temperature About 18 C to 32 C Indoor humidity Below approximatel...

Page 10: ...top of the panel a To latch each shaft properly insert the shaft until it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air lters Mind that you have a periodical cleaning of the air lters to prevent reducing the operation ef ciency of the product Using of clogged air lter with dust will lower the product performance and may c...

Page 11: ...is left with the package opened Replace the lter once every 3 months under normal use By setting the fan speed high the air cleaning effect increases Ion deodorization lter UTR FA16 2 Light blue 1 sheet The lter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra ne particle ceramic To maintain the deodorizing effect clean the...

Page 12: ...ode the indoor unit fan may stop from time to time when the outdoor unit is stopped 4 When monitoring operation is performed in AUTO mode the fan rotates at very low speed Before you call for or request servicing troubleshoot a problem by performing following checks Symptom Diagnostic See page Does not operate at all Has the circuit breaker been turned off Has there been a power outage Has a fuse ...

Reviews: