En-7

 7.  ENERGY SAVING OPERATIONS

7.1. Economy operation

It saves more electricity than other operation modes by changing the set 
temperature to a moderate setting.

Press 

 to activate/deactivate the Economy 

operation.

[   ] indicator on the indoor unit will turn on.

Operation 

mode

Room temperature

Cooling/Dry

Few degrees higher than the set temperature

Heating

Few degrees lower than the set temperature

NOTES:

•  In the Cooling, Heating, or Dry mode, the maximum output of this 

operation is approximately 70 % of usual operation.

•  This operation cannot be performed during the temperature 

monitoring by the Auto mode.

 7.2.  Human sensor for energy saving

 

WARNING

•  Do not use this function when there are only infants, 

children, elderly, or sick persons in the room.

 

CAUTION

•  Do not use this function in server rooms or other 

places where there is no one in the room.

•  Do not place large objects near the human sensor. 

Also keep heating units outside the sensor’s detection 

area.

When no one is in the room, the air conditioner operates moderately to 
prevent waste of electricity.
(This function is activated at the time of purchase.)

To change the setting, press 

 .

While the Energy Saving program is activated, 

 on the 

remote controller display will turn on.

NOTES:

•  The following operations will override the Energy Saving program.

 

- Sleep timer operation

 

- 10 

˚

C Heat operation

•  The Energy Saving program may not work when the room 

temperature is very different from the set temperature, such as 
when immediately after starting the operation.

 

Details on Energy Saving program

Human sensor on the indoor unit detects movement of people.
If there is no one in the room for approximately 20 minutes, the 
temperature will be adjusted moderately.
When someone comes back into the room, the air conditioner revert to 
the original settings.

Operation 

mode

Room temperature

(When there is no one there)

Cooling/Dry

Higher than the set temperature (Max. +2

˚

C)

Heating

Lower than the set temperature (Max. -4

˚

C)

Auto

Depending on the operating mode (Cooling/ Heating/ 
Dry).

Detection range of Human sensor

90°

7 m

7 m

50°

50°

Side view

Top view

NOTES: 

Since Human sensor detects infrared light given out by people, 

the detection may be incorrect in the following situations.

Situations in which the sensor may detect no one in the room, 
even when there is someone there:

•  When the room temperature is high and the difference with people’s 

body temperature is small. (Such as when the temperature is 30

˚

or higher in summer.)

•  When someone in the room do not move for a long time.
•  When someone is hidden behind a sofa, other furniture, glass, or in 

similar situations.

•  When someone is wearing extremely thick clothing and turn their 

backs on the sensor.

Situations in which the sensor may detect people in the room, even 
when there is no one there

•  When there is a dog or a cat moving around in the room.
•  When wind is moving curtains or plants.
•  When heating units, humidi

fi

 ers, or electric appliances such as 

oscillating electric fans are operating.

 7.3.  Fan control for energy saving

 In the Cooling operation, when the room 
temperature reaches the set temperature, the 
indoor unit fan rotates intermittently to save 
power. (This function is activated at the time of 
purchase.)

To change the setting, use the following 

steps;

1. 

Press   until only the clock is displayed on the remote 

controller display.

2. 

Press and hold 

 for more than 5 seconds.

The current Fan Control status ( 

 ) is displayed.

3. 

Press 

 to switch between activated ( 

 ) or 

deactivated ( 

 ).

4. 

Press   to send the setting to the indoor unit.

The display will return to the original screen.

NOTES:

 If you do not press any buttons for 30 seconds after 

 is 

displayed, 

 will turn off. In this case, repeat the setting from 

step 2.

During the Sleep timer operation, the setting temperature changes as 
the following 

fi

 gure.

In Heating mode

Set
temperature

Set time

1 hour

Set time

1 hour

1.5 hour

30 min.

1 °C 2 °C 3 °C 4 °C

2 °C

1 °C

In Cooling or Dry mode

After the set time has elapsed, the air conditioner operation turns off.

9387081244_OM.indb   7

9387081244_OM.indb   7

8/26/2019   6:31:56 PM

8/26/2019   6:31:56 PM

Summary of Contents for ASF30K-KM

Page 1: ...ε να ανατρέχετε σε αυτό στο μέλλον MANUAL DE FUNCIONAMENTO AR CONDICIONADO Tipo mural Antes de utilizar este produto leia atentamente estas instruções e guarde este manual para referência futura РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ КОНДИЦИОНЕР ВОЗДУХА Настенного типа Перед эксплуатацией устройства внимательно ознакомьтесь с данным руководством и сохраняйте его для использования в будущем KULLANIM KILAVUZU ...

Page 2: ...are not to damage the power supply cable If it is damaged it should be replaced only by authorized service personnel in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning strike turn off the air conditioner via the remote controller and...

Page 3: ...door unit clean and tidy and do not place items around it Any objects blocking or entering from the outlet ports may cause product malfunction Do not direct the airflow at fireplaces or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product Do not place any oth...

Page 4: ...ep press the button again For Basic operations Refer to page 5 Starts or stops the air conditioner operation Changes the operation mode Adjusts the setting temperature For 10 C Heat operation Refer to page 8 Activates the 10 C Heat operation 3 NAME OF PARTS CAUTION For appropriate signal transmission between the remote controller and the indoor unit keep the signal receiver away from the following...

Page 5: ...he clock setting After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET CAUTION To prevent malfunction or damage of the remote controller Place remote controller at where will not be exposed to direct sunlight or excessive heat Remove batteries if the product is not going to be used for an extended period Obstacles such...

Page 6: ...s to set the desired temperature The temperature changes by 0 5 C increments Temperature setting range Auto Cooling Dry 18 0 30 0 C Heating 16 0 30 0 C NOTES In the Cooling or Dry mode set the temperature lower than the current room temperature the indoor unit fan may stop from time to time to perform Fan control for energy saving that enables power saving operation by stopping the rotation of the...

Page 7: ...ll be deactivated In such a case activate the Weekly timer after the other timer finishes If the wired remote controller optional is connected this function is restricted Day of the week Program number Without a timer On timer Off timer Examples of Weekly timer Example 1 7 00 9 00 11 00 17 00 23 00 Monday to Friday Program 1 Program 2 Program 3 Program 4 On Off On Off 26 C 28 C Wake up Leave for w...

Page 8: ...the set temperature Max 4 C Auto Depending on the operating mode Cooling Heating Dry Detection range of Human sensor 90 7 m 7 m 50 50 Side view Top view NOTES Since Human sensor detects infrared light given out by people the detection may be incorrect in the following situations Situations in which the sensor may detect no one in the room even when there is someone there When the room temperature ...

Page 9: ... this function is restricted 9 SETTINGS ON INSTALLATION 9 1 Remote controller custom code setting By setting custom code of indoor unit and remote controller you can specify the air conditioner which the remote controller controls When two or more air conditioners are in the room and you wish to operate them separately set the custom code 4 selections possible NOTES If custom codes is different be...

Page 10: ...ir cleaning filters into the air cleaning filter frames NOTES Use the Apple catechin filter as soon as possible after opening the package The air cleaning effect decreases when the filters are left in the opened package The frequency of the cleaning is as shown in the following table What to do Frequency Cleaning indoor unit body When you notice Cleaning intake grille Cleaning air filter Every 2 w...

Page 11: ...th high humidity frost may form on the outdoor unit during the heating operation and it could reduce the operating performance of the product For frost protection a microcomputer controlled automatic defrost function is equipped in this air conditioner If frost forms the air conditioner will temporarily stop and defrost circuit will operate briefly maximum of 15 minutes indicator on the indoor uni...

Page 12: ...n your screen Step 2 User registration 1 Open the installed mobile app 2 Register the user with either a smartphone or tablet PC by following the instructions in the create an account section of the mobile app Wireless LAN label MAC SSID AP WF PIN Connection port Step 3 Installing W LAN adapter CAUTION Be sure to turn off the power supply of the air conditioner when installing or removing this pro...

Page 13: ...t press any buttons of the remote controller for 60 seconds the remote controller display will return to the original display 1 Press until only the clock is displayed on the remote controller display 2 Press down on the remote controller for more than 5 seconds will be displayed on the remote controller display 3 Select using on the remote controller 4 Press indicator on the indoor unit will turn...

Page 14: ... unit is connected to the power supply it is not insulated from the power supply even if the unit is turned off Unit smells of something burning or emits smoke Water leaks from the unit Does not operate at all Has there been a power outage In this case the unit restarts automatically after the power supply is resumed Refer to page 10 Has the circuit breaker been turned off Turn on the circuit brea...

Page 15: ...ere is a possibility that the W LAN adapter is not properly connected to the wireless router 11 Disconnect the power supply to the air conditioner via breaker or plug and then re connect The software of the W LAN adapter is being updated During the air conditioner registration pairing of W LAN adapter 11 Restricted function 11 Manual Auto operation and Filter indicator reset You can operate the ai...

Reviews: