background image

En-5

 5. AIRFLOW SETTINGS

5.1.  Fan speed setting

 Press 

 to control the fan speed.

The fan speed changes as follows.

(Auto)

(High)

(Med)

(Low)

(Quiet)

When 

 is selected, the fan speed depends on the operating 

condition.
To increase the air cleaning effect, set the fan speed to High.

 5.2. Air

fl

 ow direction setting

For details of the air

fl

 ow ranges, refer to "Air

fl

 ow direction 

range".

 

Vertical air

fl

 ow direction setting

Press 

 to adjust the vertical air

fl

 ow direction.

 

Horizontal air

fl

 ow direction setting

Press 

 to adjust the horizontal air

fl

 ow direction.

 

Swing operation setting

Press 

 to select the Swing operation.

The Swing operation changes as follows.

 Up/down 

Left/right 

Up/down/left/right 

Stop swing

NOTES:

 The Swing operation may stop temporarily when the indoor 

unit fan is rotating at very low speed or is stopped.

 6. TIMER OPERATIONS

NOTES: 

When [   ] indicator on the indoor unit blinks, set the clock 

and timer again. This blinking shows that the internal clock go 
wrong due to an interruption of the power supply. (Refer to 
page 10.)

 

Timer setting procedure

Before setting the timer, please adjust the clock. (Refer to "remote 
controller preparation").

1. 

Press 

.

 on the remote controller display will blink.

2. 

Press 

(

)

 to choose timer operation.

The timer operation will change as follows:

[

]

[

]

[

]

Weekly timer

Enables you to set operation 
schedules up to 4 setting for each 
day of the week.

On timer

Starts the operation at your desired 
time.

Off timer

Stops the operation at your desired 
time.

Program timer

Operates as the combination of the 
On timer and Off timer.

Sleep timer

Supports your comfortable sleep 
by moderating the air conditioner 
operation gradually.

3. 

Press 

.

4. 

Set each timer operation.

For details, refer to the following instructions of each timer setting.

5. 

Press 

 to complete the timer setting.

Be close to the indoor unit.

•  To cancel the timer setting during the procedure, press 

 

again.

 4. BASIC OPERATIONS

 

3 steps to start operation

1. 

Press 

 to start or stop the operation.

2. 

Press 

 to select the operation mode.

The operation mode changes as follows.

AUTO  

COOL  

DRY  

FAN  

HEAT

3. 

Press 

 to set the desired temperature.

The temperature changes by 0.5 °C increments.

Temperature setting range

Auto/Cooling/Dry

18.0 - 30.0 °C

Heating

16.0 - 30.0 °C

NOTES:

•  In the Cooling or Dry mode,

 

- set the temperature lower than the current room temperature.

 

- the indoor unit fan may stop from time to time to perform Fan 

control for energy saving that enables power-saving operation by 

stopping the rotation of the indoor unit fan when the outdoor unit is 

stopped. 

In initial setting, this function is activated. 

To deactivate the function, refer to the page 7.

•  In the Heating mode,

 

- set the temperature higher than the current room temperature.

 

- at the beginning of the operation, the indoor unit fan rotates at very 

low speed for 3-5 minutes.

 

- the Automatic defrosting operation overrides the Heating operation 

when necessary.

•  In the Fan mode, temperature control is not available. 

 

Temperature unit switching

1. 

Press 

 until only the clock is displayed.

2. 

Press and hold 

 for more than 5 seconds.

The current temperature unit will be displayed. (Factory setting: °C)

3. 

Press 

 to switch the temperature unit. (°C 

°F)

4. 

Press 

 to 

fi

 nish the setting.

If you do not press the button for 30 seconds, the displayed 
temperature unit will be set.

 

Air

fl

 ow direction range

Vertical air

fl

 ow direction

1

2

3

4

5

6

Change by 

 

1

2

3

4

5

6

Swing operation by 

Cooling, Dry

1

4

Heating

3

6

Fan *

1

4 or 3

6

* The Swing operation range depends on the air

fl

 ow direction set before 

the Swing operation.

NOTES:

•  Do not adjust the air

fl

 ow direction louvers by hand.

•  In the Auto or Heating mode, the air

fl

 ow direction stay position 1 for 

a while from the start of the operation.

•  In the Cooling or Dry mode, position 1-3 is recommended to prevent 

condensation drips damaging your property. If position 4-6 keeps for 
30 minutes or more in these modes, the air

fl

 ow direction changes to 

position 3 automatically.

•  When using the mobile app (optional wireless LAN control is 

necessary), the vertical air

fl

 ow can be selected from 4 positions.

Horizontal air

fl

 ow direction

3

4

5

2

1

Change by 

 

1

2

3

4

5

Swing operation 
by 

1

5

NOTES: 

In the Auto mode operation, you cannot change the air

fl

 ow 

direction for a while from the start of the operation.

9387081244_OM.indb   5

9387081244_OM.indb   5

8/26/2019   6:31:56 PM

8/26/2019   6:31:56 PM

Summary of Contents for ASF30K-KM

Page 1: ...ε να ανατρέχετε σε αυτό στο μέλλον MANUAL DE FUNCIONAMENTO AR CONDICIONADO Tipo mural Antes de utilizar este produto leia atentamente estas instruções e guarde este manual para referência futura РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ КОНДИЦИОНЕР ВОЗДУХА Настенного типа Перед эксплуатацией устройства внимательно ознакомьтесь с данным руководством и сохраняйте его для использования в будущем KULLANIM KILAVUZU ...

Page 2: ...are not to damage the power supply cable If it is damaged it should be replaced only by authorized service personnel in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning strike turn off the air conditioner via the remote controller and...

Page 3: ...door unit clean and tidy and do not place items around it Any objects blocking or entering from the outlet ports may cause product malfunction Do not direct the airflow at fireplaces or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product Do not place any oth...

Page 4: ...ep press the button again For Basic operations Refer to page 5 Starts or stops the air conditioner operation Changes the operation mode Adjusts the setting temperature For 10 C Heat operation Refer to page 8 Activates the 10 C Heat operation 3 NAME OF PARTS CAUTION For appropriate signal transmission between the remote controller and the indoor unit keep the signal receiver away from the following...

Page 5: ...he clock setting After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET CAUTION To prevent malfunction or damage of the remote controller Place remote controller at where will not be exposed to direct sunlight or excessive heat Remove batteries if the product is not going to be used for an extended period Obstacles such...

Page 6: ...s to set the desired temperature The temperature changes by 0 5 C increments Temperature setting range Auto Cooling Dry 18 0 30 0 C Heating 16 0 30 0 C NOTES In the Cooling or Dry mode set the temperature lower than the current room temperature the indoor unit fan may stop from time to time to perform Fan control for energy saving that enables power saving operation by stopping the rotation of the...

Page 7: ...ll be deactivated In such a case activate the Weekly timer after the other timer finishes If the wired remote controller optional is connected this function is restricted Day of the week Program number Without a timer On timer Off timer Examples of Weekly timer Example 1 7 00 9 00 11 00 17 00 23 00 Monday to Friday Program 1 Program 2 Program 3 Program 4 On Off On Off 26 C 28 C Wake up Leave for w...

Page 8: ...the set temperature Max 4 C Auto Depending on the operating mode Cooling Heating Dry Detection range of Human sensor 90 7 m 7 m 50 50 Side view Top view NOTES Since Human sensor detects infrared light given out by people the detection may be incorrect in the following situations Situations in which the sensor may detect no one in the room even when there is someone there When the room temperature ...

Page 9: ... this function is restricted 9 SETTINGS ON INSTALLATION 9 1 Remote controller custom code setting By setting custom code of indoor unit and remote controller you can specify the air conditioner which the remote controller controls When two or more air conditioners are in the room and you wish to operate them separately set the custom code 4 selections possible NOTES If custom codes is different be...

Page 10: ...ir cleaning filters into the air cleaning filter frames NOTES Use the Apple catechin filter as soon as possible after opening the package The air cleaning effect decreases when the filters are left in the opened package The frequency of the cleaning is as shown in the following table What to do Frequency Cleaning indoor unit body When you notice Cleaning intake grille Cleaning air filter Every 2 w...

Page 11: ...th high humidity frost may form on the outdoor unit during the heating operation and it could reduce the operating performance of the product For frost protection a microcomputer controlled automatic defrost function is equipped in this air conditioner If frost forms the air conditioner will temporarily stop and defrost circuit will operate briefly maximum of 15 minutes indicator on the indoor uni...

Page 12: ...n your screen Step 2 User registration 1 Open the installed mobile app 2 Register the user with either a smartphone or tablet PC by following the instructions in the create an account section of the mobile app Wireless LAN label MAC SSID AP WF PIN Connection port Step 3 Installing W LAN adapter CAUTION Be sure to turn off the power supply of the air conditioner when installing or removing this pro...

Page 13: ...t press any buttons of the remote controller for 60 seconds the remote controller display will return to the original display 1 Press until only the clock is displayed on the remote controller display 2 Press down on the remote controller for more than 5 seconds will be displayed on the remote controller display 3 Select using on the remote controller 4 Press indicator on the indoor unit will turn...

Page 14: ... unit is connected to the power supply it is not insulated from the power supply even if the unit is turned off Unit smells of something burning or emits smoke Water leaks from the unit Does not operate at all Has there been a power outage In this case the unit restarts automatically after the power supply is resumed Refer to page 10 Has the circuit breaker been turned off Turn on the circuit brea...

Page 15: ...ere is a possibility that the W LAN adapter is not properly connected to the wireless router 11 Disconnect the power supply to the air conditioner via breaker or plug and then re connect The software of the W LAN adapter is being updated During the air conditioner registration pairing of W LAN adapter 11 Restricted function 11 Manual Auto operation and Filter indicator reset You can operate the ai...

Reviews: