En-10
9.
Install the air cleaning
fi
lter holders to the air
fi
lters.
Engage the 2 hooks at the rear of the air cleaning
fi
lter frame with
the latch at both ends of the air
fi
lter.
Hook (2 places at the rear)
Latch (2 places)
NOTES:
Take care that the air cleaning
fi
lter does not project
beyond the frame.
10.
Engage the six
fi
xing locations at the top and bottom of the
air cleaning
fi
lter holder with the hooks of the air
fi
lter.
Rear of the
fi
lter
Fixing location,
hook (6 places)
11.
Replace the air
fi
lters and close the intake grille. Refer to
steps 4 ~ 5 of "Cleaning air
fi
lter".
Replacing Ion deodorization
fi
lter
1.
Remove the air
fi
lters. Refer to steps 1 ~ 2 of "Cleaning air
fi
lter".
2.
Remove the Ion deodorization
fi
lter (light blue) from the air
cleaning
fi
lter holder.
3.
Install the new Ion deodorizing
fi
lter.
After extended non-use of the unit
If you have shut down the indoor unit for 1 month or more, perform the
Fan mode operation for half a day to dry the internal parts thoroughly
before the normal operation.
Additional inspection
After long period of use, accumulated dust inside the indoor unit may
reduce the performance even if you have maintained the unit properly.
In such a case, a product inspection is recommended.
For more information, consult authorized service personnel.
Filter indicator reset (Special setting)
This function can be used if set correctly during installation. Please
consult authorized service personnel in order to use this function.
Clean the air
fi
lter when the indicator lamp show the
following:
Indicator lamp
Blinking pattern
Blinks 3 times, at intervals of 21 seconds
After cleaning, reset the
fi
lter indicator by pushing
on the
indoor unit for 2 seconds or less.
11. GENERAL INFORMATION
■
Heating performance
This air conditioner operates on the heat-pump principle, absorbing heat
from air outdoors and transferring that heat to the indoor unit. As a result,
the operating performance is reduced as outdoor air temperature drops.
If you feel that the heating performance is insuf
fi
cient, we recommend
you to use this air conditioner in conjunction with other kinds of heating
appliance.
■
Automatic defrosting operation
When outdoor temperature is very low with high humidity, frost may
form on the outdoor unit during the heating operation, and it could
reduce the operating performance of the product.
For frost protection, a microcomputer-controlled automatic defrost
function is equipped in this air conditioner.
If frost forms, the air conditioner will temporarily stop, and defrost circuit
will operate brie
fl
y (maximum of 15 minutes.)
[ ] indicator on the indoor unit blinks during this operation.
If frost forms on the outdoor unit after the Heating operation, the outdoor
unit will stop automatically after it operates for a few minutes. Then the
Automatic defrosting operation starts.
■
Auto-restart function
In event of power interruption such as a blackout, the air conditioner
stops once. But it restarts automatically and performs previous operation
when the power supply is resumed.
If any power interruption occurs after the timer is set, counting down of
the timer will be reset.
After the power supply is resumed, [ ] indicator on the indoor unit
blinks to notify you that there has been a timer fault. In such a case,
reset the clock and timer settings.
■
Malfunctions caused by other electrical
devices
Use of other electrical appliances such as an electric shaver or nearby
use of a wireless radio transmitter may cause the malfunction of the air
conditioner.
If you encounter such a malfunction, turn off the circuit breaker once.
Then turn it on again, and resume operation by using the remote
controller.
■
Indoor unit temperature and humidity range
Permissible ranges of temperature and humidity are as follows:
Indoor temperature
Cooling/Dry
[°C]
18 to 32
Heating
[°C]
16 to 30
Indoor humidity
[%]
80 or less *
1)
*1) If the air conditioner is used continuously for many hours, water may
condense on the surface and drip.
• If the unit is operated under the conditions except the permissible
temperature range, the air conditioner operation may stop because
of the automatic protection circuit working.
• Depending on the operating conditions, the heat exchanger may
freeze, causing water leakage or other malfunction (in the Cooling
or Dry mode).
■
Other information
• Do not use the air conditioner for any purpose other than room
cooling/dry, room heating or fan.
• For the permissible ranges of temperature and humidity for the
outdoor unit, refer to the outdoor unit installation manual.