En-9
Cleaning air
fi
lter
1.
Open the intake grille until it snaps.
2.
Remove the air
fi
lters.
Lift up the air
fi
lters' handle, disconnect the two lower tabs, and pull
out.
Air
fi
lter handle
Tabs (2 places)
3.
Remove the dust in either of the following ways.
• Cleaning with vacuum cleaner.
• Washing with mild detergent and warm water. After washing, dry the
air
fi
lters thoroughly in shade.
4.
Replace the air
fi
lters.
Align the sides of the air
fi
lter with the panel, and push in fully.
Make sure to the two lower tabs are returned to their holes in the
indoor unit properly.
5.
Close the intake grille.
Press 4 places on the intake grille to close it completely.
NOTES:
If dirt accumulates on the air
fi
lter, air
fl
ow will be reduced,
operating ef
fi
ciency will lower, and the noise will increase.
Cleaning Ion deodorization
fi
lter and
Replacing Apple-catechin
fi
lter
1.
Remove the air
fi
lters. Refer to steps 1 ~ 2 of "Cleaning air
fi
lter".
2.
Remove the air cleaning
fi
lters from the air cleaning
fi
lter
holder.
Air cleaning
fi
lter
Air cleaning
fi
lter holder
3.
Flush the Ion deodorization
fi
lter (light blue) with high-
pressure hot water until the surface of the
fi
lters are covered
with water.
4.
Wash the Ion deodorization
fi
lter with diluent neutral
detergent.
Do not ream or rub, otherwise the deodorizing effect may decrease.
5.
Rinse the Ion deodorization
fi
lter with water
fl
ow.
6.
Dry the Ion deodorization
fi
lter in shade.
7.
Remove the Apple-catechin
fi
lter (light green) from the air
cleaning
fi
lter holder.
8.
Set the new or washed air cleaning
fi
lters into the air
cleaning
fi
lter frames.
NOTES:
Use the Apple-catechin
fi
lter as soon as possible after opening
the package. The air cleaning effect decreases when the
fi
lters
are left in the opened package.
The frequency of the cleaning is as shown in the following table.
What to do
Frequency
Cleaning indoor unit body
When you notice
Cleaning intake grille
Cleaning air
fi
lter
Every 2 weeks
Cleaning Ion deodorization
fi
lter
Every 3 months
Replacing Apple-catechin
fi
lter
(Model name: UTR-FA13-1)
Replacing Ion deodorization
fi
lter
(Model name: UTR-FA13-2)
Every 3 years
* The air cleaning
fi
lters are sold separately. When you replace them,
please contact the store of purchase.
Cleaning indoor unit body
NOTES:
• Do not use water hotter than 40 °C.
• Do not use scouring cleanser, volatile solvents such as benzene or
thinner.
1.
Wipe the indoor unit body gently with a soft cloth moisten
with warm water.
2.
Wipe the indoor unit body gently with a dry and soft cloth.
Cleaning intake grille
■
Removing intake grille
1.
Open the intake grille.
2.
While pressing the left and right mounting shafts outward
gently, pull the intake grille.
■
Cleaning intake grille
1.
Wash the intake grille gently with water or wipe it gently with
a soft cloth moisten with warm water.
2.
Wipe the intake grille with a dry and soft cloth.
■
Installing intake grille
1.
While holding the intake grille horizontal, set the left and
right mounting shafts into the pillow blocks at the top of the
front panel.
Insert the shaft until it snaps to latch each shaft properly.
2.
Close the intake grille.
3.
Press 4 places on the intake grille to close it completely.
9387081244_OM.indb 9
9387081244_OM.indb 9
8/26/2019 6:31:57 PM
8/26/2019 6:31:57 PM