4.  TIMER OPERATIONS

NOTES:

  In simultaneous multi connection, this function by using the 

wireless remote controller cannot be used.

4.1.  On timer or Off  timer

NOTES:

  Depending on the remote controller, this function may not be 

available.

The On timer starts the operation at your desired time.
The Off  timer stops the operation at your desired time.

4.2.  Weekly timer

NOTES: 

This function is available only by the wired remote controller.

The Weekly timer enables you to set operation schedules up to 4 setting 
for each day of the week.
Use the Day off  setting to switch off  timed operation for a selected day 
in the coming week. Because all days can be set together, the weekly 
timer can be used to repeat the timer settings for all of the days.

Temperature setting range

Auto, Cooling,
or Dry mode:

18-30 °C
*Even if you set to 10, 16, or 17 °C, the air 

conditioner will run at 18 °C.

Heating mode: 

10 or 16-30 °C

•  The operation modes will be the same as the mode at the last 

time operation was stopped. So Cooling → Heating → Cooling → 
Heating type of operations cannot be set automatically.

•  If you set the On timer and Off  timer on the same time, the On timer 

will work.

•  If two On timers are set on the same time, the air conditioner will run 

in the order of the program number.

•  You cannot the Weekly timer and the other timers simultaneously 

If you use the On/Off  timer, the Program timer, or the Sleep timer 
while the Weekly timer is activated, the Weekly timer will be 
deactivated.
In such a case, activate the Weekly timer after the other timer 
fi nishes.

4.3.  Program timer

NOTES:

 This function is available only when using the wireless remote 

controller.

The Program timer operates as the combination of the On timer and Off  
timer.
You can set the Program timer only within a span of 24 hours.

4.4.  Sleep timer

NOTES:

 This function is available only when using the wireless remote 

controller.

The Sleep timer supports your comfortable sleep by moderating the air 
conditioner operation gradually.
The time setting of the Sleep timer changes as follows:

9H

00M

7H

00M

5H

00M

3H

00M

2H

00M

1H

00M

0H

30M

hours

(30 min.)

During the Sleep timer operation, the setting temperature changes as 
the following fi gure.

In Heating mode

Set
temperature

Set time

1 hour

Set time

1 hour

1.5 hour

30 min.

1 °C 2 °C 3 °C 4 °C

2 °C

1 °C

In Cooling or Dry mode

After the set time has elapsed, the air conditioner operation turns off .

 

Cooling mode

Use to cool your room.

NOTES:

•  Set the temperature lower than the current room temperature, 

otherwise, the fan alone will operate.

•  The indoor unit fan may stop from time to time because of the Fan 

control for energy saving (refer to page 4).

 

Dry mode

Use for gently cooling while dehumidifying your room.

NOTES:

•  You cannot heat the room.
•  Set the temperature lower than the current room temperature, 

otherwise, the operation will not operate.

•  The unit will operate at low speed in order to adjust room humidity. 

The indoor unit’s fan may stop from time to time. Also, the fan may 
operate at very low speed when adjusting room humidity.

•  The fan speed cannot be changed manually.

 

Fan mode

Use to circulate the air throughout your room.

NOTES: 

You cannot set the temperature.

 

Heating mode

Use to warm your room.

NOTES:

•  Set the temperature higher than the current room temperature, 

otherwise, the operation will not operate.

•  At the beginning of the operation, the indoor unit fan rotates at very 

low speed for 3-5 minutes to warm the internal indoor unit. After the 
period, the indoor unit fan will switch to the selected fan speed. 

•  When the room temperature is very low, frost may form on the 

outdoor unit, and its performance may be reduced. In order to 
remove such frost, the unit will automatically enter the defrost 
cycle from time to time. During Automatic defrosting operation, the 
Heating operation will be interrupted.

•  After the start of Heating operation, it takes sometime before the 

room gets warmer.

3.  AIRFLOW SETTINGS

NOTES:

 For detailed instructions on how to operate, please refer to the 

operating manual of the remote controller.

3.1.  Fan speed setting

The fan speed changes as follows.

When Auto is selected, the fan speed is automatically adjusted 
according to the operation mode. 

Heating:

The fan will operate at very low speed when the 
temperature of the air issued from the indoor unit is low.

Cooling:

As the room temperature approaches that of the set 
temperature, the fan speed becomes slower.

Fan:

The fan runs at low fan speed.

The fan will operate at a very low setting during monitor operation and 
at the start of the heating mode.

When Quiet is selected, Super Quiet operation begins. The indoor unit’s 
airfl ow will be reduced for quieter operation.
●   The Super Quiet operation cannot be used during the Dry mode. (The 

same is true when the Dry mode is selected during the Auto mode 
operation.)

●   During the Super Quiet operation, heating and cooling performance 

will be reduced somewhat. If the room does not warm up/ cool down 
when using the Super Quiet operation, please adjust the indoor unit’s 
fan speed.

Auto

High

Med

Low

Quiet

9383813009_OM.indb   3

9383813009_OM.indb   3

12/12/2018   9:03:03 AM

12/12/2018   9:03:03 AM

Summary of Contents for ARXG12-54KHTAP

Page 1: ...ΣΤΙΚΟ Τύπος αγωγού Προτού χρησιμοποιήσετε το προϊόν διαβάστε προσεκτικά τις παρούσες οδηγίες και φυλάξτε το παρόν εγχειρίδιο ώστε να μπορείτε να ανατρέχετε σε αυτό στο μέλλον MANUAL DE FUNCIONAMENTO AR CONDICIONADO Tipo conduta Antes de utilizar este produto leia atentamente estas instruções e guarde este manual para referência futura РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ КОНДИЦИОНЕР ВОЗДУХА Канального типа...

Page 2: ...lways consult authorized service personnel for repairing installation and relocation of this product Improper installation or handling will cause leakage electric shock or fire In the event of a malfunction such as burning smell immediately stop operation of the air conditioner and disconnect all the power supply by turning off the electrical breaker or disconnecting the power plug Then consult auth...

Page 3: ...aces or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product CAUTION Do not place any other electrical products or household belongings under this product Dripping condensation from this product might get them wet and may cause damage or malfunction of your pr...

Page 4: ...an the current room temperature otherwise the fan alone will operate The indoor unit fan may stop from time to time because of the Fan control for energy saving refer to page 4 Dry mode Use for gently cooling while dehumidifying your room NOTES You cannot heat the room Set the temperature lower than the current room temperature otherwise the operation will not operate The unit will operate at low ...

Page 5: ...n by using the wireless remote controller cannot be used 10 C Heat operation maintains the room temperature at 10 C so as to prevent the room temperature to drop too low NOTES When the room temperature is warm enough This operation will not be performed In case of multi type air conditioner if other indoor unit is used for heating the temperature of the room where the 10 C Heat operation is applie...

Page 6: ...tructions on how to operate please refer to the operating manual of the remote controller 8 GENERAL INFORMATION Inverter On start up the air conditioner will operate at maximum capacity to bring the room quickly down to desired temperature Once the temperature in the room begins to achieve the set temperature the air conditioner will reduce its capacity and energy usage to the minimum capacity and...

Page 7: ...ectable indoor units and connectable type of the separation tube vary by model Depending on model this function cannot be used For details please consult authorized service personnel In simultaneous multi connection all indoor units can be operated simultaneously from one remote controller connected to the primary indoor unit For this unique characteristic of the simultaneous multi connection the ...

Page 8: ...mode Do you hear a sizzling sound This sound is produced by the Automatic defrosting operation Refer to page 5 Smell coming from the unit The air conditioner may absorb various smells generated from interior textile furniture or cigarette smoke These smells may be emitted during the operation Mist or steam is emitted from the unit In the Cooling or Dry mode A thin mist may be generated by condensa...

Reviews: