background image

En-7

 

<In the Heating mode> Have you just started the operation? 
In this case, the fan rotates at very low speed temporarily to warm 
up the internal parts of the unit.

 

<In the Heating mode> Is the room temperature higher than the 
set temperature? 
In this case, the outdoor unit stops and the indoor unit fan rotates 
at very low speed. 

 

<In the Heating mode> Is the Automatic defrosting operation 
working? In this case, the indoor unit stops for maximum of 15 
minutes. (Refer to 

page 5

.)

 

<In the Dry mode> The indoor unit operates at low fan speed to 
adjust the room humidity, and may stop from time to time.

 

<In the Auto mode> While the monitoring operation, the fan 
rotates at very low speed.

 

<In multi connection> Are multiple units set in diff erent operation 
mode as shown below? 
In this case, the units set afterward will stop.
• Heating mode and other mode

Humidity does not drop.

 

<In the Dry operation> If the setting temperature is high, the 
humidity may not drop.

⇒ 

To lower the humidity, lower the setting temperature.

Noise is heard.

 

Is the unit operating, or immediate after stopping operation?
In this case, refrigerant fl owing sound may be heard. It may be 
particularly noticeable for 2-3 minutes after starting operation.

 

Do you hear a slight squeaking sound during the operation? 
This sound is produced by the minute expansion and contraction 
of the front panel caused by temperature change.

 

<In the Heating mode> Do you hear a sizzling sound? 
This sound is produced by the Automatic defrosting operation. 
(Refer to 

page 5

.)

Smell coming from the unit.

 

The air conditioner may absorb various smells generated from 
interior textile, furniture, or cigarette smoke. These smells may be 
emitted during the operation.

Mist or steam is emitted from the unit.

 

<In the Cooling or Dry mode> A thin mist may be generated by 
condensation formed with sudden cooling process.

 

<In the Heating mode> Is the Automatic defrosting operation 
working? In this case, steam may rise from the outdoor unit. (Re-
fer to 

page 5

.)

Outdoor unit emits water.

 

<In the Heating mode> The outdoor unit may emit water gener-
ated by the Automatic defrosting operation. (Refer to 

page 5

.)

Operation is delayed after restart.

 

Has the power supply turned from off  to on suddenly? 
In this case, the compressor will not operate for about 3 minutes 
to prevent a blowout of the fuse.

 

Has the electrical breaker is turned off  then on again?
In this case, the protection circuit will operate for about 3 minutes.

Immediately stop operation and turn off  the electrical breaker in 

following cases. Then consult authorized service personnel.

•  The problem persists even if you perform these checks or 

diagnostics.

•  Error sign is shown on the wired remote controller display or the 

indicator lamps on the IR receiver unit.

NOTES:

For any troubleshooting related to the W-LAN control, refer to the 
setting manual for W-LAN adapter or the mobile app installed in your 
smartphone or tablet PC.

9383813009_OM.indb   7

9383813009_OM.indb   7

12/12/2018   9:03:04 AM

12/12/2018   9:03:04 AM

Summary of Contents for ARXG12-54KHTAP

Page 1: ...ΣΤΙΚΟ Τύπος αγωγού Προτού χρησιμοποιήσετε το προϊόν διαβάστε προσεκτικά τις παρούσες οδηγίες και φυλάξτε το παρόν εγχειρίδιο ώστε να μπορείτε να ανατρέχετε σε αυτό στο μέλλον MANUAL DE FUNCIONAMENTO AR CONDICIONADO Tipo conduta Antes de utilizar este produto leia atentamente estas instruções e guarde este manual para referência futura РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ КОНДИЦИОНЕР ВОЗДУХА Канального типа...

Page 2: ...lways consult authorized service personnel for repairing installation and relocation of this product Improper installation or handling will cause leakage electric shock or fire In the event of a malfunction such as burning smell immediately stop operation of the air conditioner and disconnect all the power supply by turning off the electrical breaker or disconnecting the power plug Then consult auth...

Page 3: ...aces or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product CAUTION Do not place any other electrical products or household belongings under this product Dripping condensation from this product might get them wet and may cause damage or malfunction of your pr...

Page 4: ...an the current room temperature otherwise the fan alone will operate The indoor unit fan may stop from time to time because of the Fan control for energy saving refer to page 4 Dry mode Use for gently cooling while dehumidifying your room NOTES You cannot heat the room Set the temperature lower than the current room temperature otherwise the operation will not operate The unit will operate at low ...

Page 5: ...n by using the wireless remote controller cannot be used 10 C Heat operation maintains the room temperature at 10 C so as to prevent the room temperature to drop too low NOTES When the room temperature is warm enough This operation will not be performed In case of multi type air conditioner if other indoor unit is used for heating the temperature of the room where the 10 C Heat operation is applie...

Page 6: ...tructions on how to operate please refer to the operating manual of the remote controller 8 GENERAL INFORMATION Inverter On start up the air conditioner will operate at maximum capacity to bring the room quickly down to desired temperature Once the temperature in the room begins to achieve the set temperature the air conditioner will reduce its capacity and energy usage to the minimum capacity and...

Page 7: ...ectable indoor units and connectable type of the separation tube vary by model Depending on model this function cannot be used For details please consult authorized service personnel In simultaneous multi connection all indoor units can be operated simultaneously from one remote controller connected to the primary indoor unit For this unique characteristic of the simultaneous multi connection the ...

Page 8: ...mode Do you hear a sizzling sound This sound is produced by the Automatic defrosting operation Refer to page 5 Smell coming from the unit The air conditioner may absorb various smells generated from interior textile furniture or cigarette smoke These smells may be emitted during the operation Mist or steam is emitted from the unit In the Cooling or Dry mode A thin mist may be generated by condensa...